2-25
2
Ba
sic O
pe
ra
tio
n
¢
Key operation in the heater control menu
Changing temperature using the heater control menu
The heater initial value that is set in MEDIA REG MENU is automatically set for the
temperature of each heater. Therefore, the heater control menu is generally not
needed. The heater control menu is used to fine-adjust the heater temperature
during printing or to monitor the current heater temperature.
¢
Heater control menu display
Aft 40
Prn
45
Pre
45
C)
40
C)
+40
C)
45
Set temperature
The “+” mark indicates that it is currently heating
After heater
Print heater
Currently selected heater
Preheater
Current temperature
- When no key is pressed for more than 30 seconds with the heater control menu displayed,
[HEATER DISPLAY END] is automatically displayed and the heater control menu display is closed.
- Even if heater temperatures are changed in the heater control menu, the initial tempera-
ture value of each heater stored in MEDIA REG MENU remains unchanged.
- When the temperature unit in SETUP MENU is set to Fahrenheit, every temperature is
displayed in Fahrenheit.
¢
To finish displaying the heater control menu
Press the
key to display the heater control menu.
and
keys
Select a heater for which temperature is to be set.
and
keys
Set the heater temperature.
key
Selects heater ON or OFF.
key
When this key is pressed for 1.5 seconds while the heater
control menu is displayed, all the heaters are forcibly acti-
vated and left ON even without print operation.
key
Pressing this key for 1.5 seconds with the heater control
menu displayed cancels the heater-on state made forcibly
by the
key. (The heater-on state is canceled and then
the printer returns to the normal control following delay
time and standby time settings.)
Press the
key while the heater control menu is displayed.