3-34
(23) PH REST PERIOD
During printing, scanning of printer heads
stops at a certain print length interval.
Use this setting to prevent print misses. Nor-
mally, set it to [0000CYCLES].
- Set the number of scan for print length in [(23) PH REST PERIOD].
- Set the rest time in [(24) PH REST TIME].
<Parameter (numeral input)>
0000 to 9999
With [0] the scan rest is not performed.
(24) PH REST TIME
Set the rest time in relation to [(23) PH REST PE-
RIOD]. When [0] is set in [(23) PH REST PERIOD],
this parameter is ignored.
Use this setting to prevent print misses. Set it
to [10 sec] as a general rule.
<Parameter (numeral input)>
1 to 99 seconds
(25) REMAINING MEDIA
Set the remaining media length. By setting the
remaining media in advance, the amount of
the remaining media after printing becomes
available in the MEDIA MENU.
Enter “***” to disable the remaining media
control.
<Parameter (numeral input)>
0 to 999 m
The input unit in the meter unit system is meter (m).
0 to 3278 ft
The input unit in the inch unit system is feet (ft).
- The parameter display unit is set in [LENGTH UNITS] of the SETUP MENU.
#PH REST TIME
>XX:10sec
#PH REST PERIOD
>XX:0000CYCLES
XX : Selected media number
XX : Selected media number
>XX:YYYYft
#REMAINING MEDIA
>XX:YYYm
XX : Selected media number
YY : Remaining media
Содержание IP-5520