ST750
G
ENERAL
H
ANDBOOK
667/HB/33750/000
Page 24
Issue 6
48V Siemens Nearside
Signal
18W
>8
No
48V Siemens Demand
Indicator
6W
>8
No
Table 3
– ST750 Lamp Load (Watts)
*Note
– ST750 LED Controllers allow these signals to be monitored. See
667/HB/32921/007 in Section 1.3.2 for further details.
Power (Watts)
Siemens ST4R/ST4S detectors
2.4 watts per
detector
Sarasota MTS36Z (2 channel) or MTS38Z (4 channel)
detectors. (NB The power consumption is the same for
both 2 and 4 channel units.)
3 watts per
detector
Microsense detectors
6 watts per
detector
Table 4
– Detector Power Consumption
A
A
B
B
C
C
C
A
D
D
A
C
2 Detector Cards used but not shown
Pedestrian Wait Indicator Box (on pole).
Pedestrian Red / Green Signal.
Traffic Red / Amber / Green Signal (Secondary)
Traffic Red / Amber / Green Signal (Primary)
Key: