Group Alarms - Central Unit
391
7SS52 V4 Manual
C53000-G1176-C182-3
10424
Supply voltage superv. BU
176.1171
15V supply supervision $00
BUnn
176.1172
5V supply supervision $00
BUnn
176.1173
0V supply supervision $00
BUnn
10443
BZ blocked selective (g. a.)
177.1333
Blocked by fault $03
BZnn
10425
Isolator fault alarm
10426
Failure of isolator aux. voltage (g.a.)
1
BUnn
10427
Isolator fault: run time (group alarm)
1
BUnn, Isoln
10428
Isolator position faulty (group alarm)
1
BUnn, Isoln
10427
Isolator fault: run time
176.1112
Fault: run time $01 isolator $02
BUnn
176.1117
Fault: run time $01 isolator $02
BUnn
176.1122
Fault: run time $01 isolator $02
BUnn
176.1127
Fault: run time $01 isolator $02
BUnn
176.1132
Fault: run time $01 isolator $02
BUnn
10428
Isolator position faulty (group alarm)
176.1113
Fault: dist. position $01 isolator $02
BUnn
176.1118
Fault: dist. position $01 isolator $02
BUnn
176.1123
Fault: dist. position $01 isolator $02
BUnn
176.1128
Fault: dist. position $01 isolator $02
BUnn
176.1133
Fault: dist. position $01 isolator $02
BUnn
10410
Diff-current superv. CZ
10411
Diff-current supervision Check Zone L1
10412
Diff-current supervision Check Zone L2
10413
Diff-current supervision Check Zone L3
10415
Diff-current superv. BZ
177.1321
Id-sup $03 L1-2
BZnn
177.1322
Id-sup $03 L2-2
BZnn
177.1323
Id-sup $03 L3-2
BZnn
177.1326
Id-sup $03 L1-3
BZnn
177.1327
Id-sup $03 L2-3
BZnn
177.1328
Id-sup $03 L3-3
BZnn
10416
Diff-current superv. BZ L1
177.1321
Id-sup $03 L1-2
BZnn
177.1326
Id-sup $03 L1-3
BZnn
10417
Diff-current superv. BZ L2
177.1322
Id-sup $03 L2-2
BZnn
177.1327
Id-sup $03 L2-3
BZnn
10418
Diff-current superv. BZ L3
177.1323
Id-sup $03 L3-2
BZnn
177.1328
Id-sup $03 L3-3
BZnn
10423
Measured value superv. BU
176.1175
Measured value superv. $00
BUnn
10429
Failure in auto testing
176.1190
Failure in automatic testing $00
BUnn
1 If
Parameter
ISOL Malfunct
(
6302/CU
) is set to
Blocking
.
2 If Parameter
DIF SUP mode CZ
(
6311/CU
) is set to
Blocking
.
3 If
Parameter
DIF SUP mode BZ
(
6310/CU
) is set to
Blocking
.
4 If
Parameter
ISOL Malfunct
(
6302/CU
) s set to
alarm only
.
5 If
Parameter
DIF SUP mode CZ
(
6311/CU
) is set to
alarm only
.
6 If
Parameter
DIF SUP mode BZ
(
6310/CU
) is set t o
alarm only
.
Group Alarm
Alarm
FNo.
Description
FNo.
Logical function
Relates to
www
. ElectricalPartManuals
. com
Содержание SIPROTEC 7SS522 V4.6
Страница 326: ...Maintenance and Repair 310 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 432: ...Appendix 416 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 438: ...Index 422 7SS52 V4 Manual C53000 G1176 C182 34 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...