List of Information - Bay Unit
FNo.
Short Text
Logical Function
Log Buffers
Configurable
in Matrix
IEC 60870-5-103
Ev
ent Log
O
n
/O
ff
Meas
u
red Val
u
e
Tr
ip (Faul
t)
Log
On/
O
ff
Bi
nar
y
Inp
u
t I
Bi
na
ry
O
ut
p
ut O
(L
E
D
, al
ar
m re
la
y
)
Tr
ip R
e
la
y
T
Data
Unit
Com
p
atibl
e
Annunci
a
ti
on
G
e
n
e
ra
l I
n
te
rr
ogation
Annu
nc. for
Fault
Rec
. Buffer
(Tagged)
Type (p: C
o
rrespond
s
t
o
param
e
ter “Function
type
“
)
In
fo
rma
tio
n
Num
b
e
r
3
>Time Synchro
>Time synchronization
IO
4
>Start FltRec
>Start fault recording
on
IO
5
>LED reset
>Reset LED indicators
IO
11
>Annunc. 1
>User defined annunciation 1
on/off
IOT
1
CA
GI
TA
p
27
12
>Annunc. 2
>User defined annunciation 2
on/off
IOT
1
CA
GI
TA
p
28
13
>Annunc. 3
>User defined annunciation 3
on/off
IOT
1
CA
GI
TA
p
29
14
>Annunc. 4
>User defined annunciation 4
on/off
IOT
1
CA
GI
TA
p
30
51
Dev.operative
Device operative / healthy
on/off
1
GI
135
81
52
Prot. operat.
Any protection operative
on/off
O
1
CA
GI
p
18
55
Re-start
Re-start of processor system
on
1
CA
p
4
56
Initial start
Initial start of processor system
on
1
CA
p
5
59
Rel.TimeResp.
Real time response to LSA
on
1
60
LED reset
LED Reset
on
O
1
CA
p
19
61
LogMeasBlock
Logging and measuring functions blocked
on/off
1
CA
GI
p
20
62
Test mode
Test mode
on/off
1
CA
GI
p
21
95
Param.running
Parameters are being set
on/off
1
CA
GI
p
22
100
Wrong SW-vers
Wrong software-version
on
101
Wrong dev. ID
Wrong device identification
on
110
Annunc. lost
Annunciations lost (buffer overflow)
on
1
135
130
111
Annu. PC lost
Annunciations for PC lost
on
112
Annu.LSA lost
Annunciations for LSA lost
on
1
135
131
113
Tag lost
Fault tag lost
1
TA
135
136
115
Flt.Buff.Over
Fault annunciation buffer overflow
on
116
E.F. Buff.Over
E/F buffer overflow
120
Oper.Ann.Inva
Operational annunciations invalid
on/off
121
Flt.Ann.Inval
Fault annunciations invalid
on/off
122
E/F.Prot Inva
Earth fault annunciations invalid
on/off
123
Stat.Buff.Inv
Statistic annunciation buffer invalid
on/off
124
LED Buff.Inva
LED annunciation buffer invalid
on/off
129
VDEW-StateInv
VDEW state invalid
on/off
135
Chs Error
Error in check sum
on/off
140
Device Fail.
General internal failure of device
on/off
1
CA
GI
p
47
143
Failure 15V
Failure of internal 15 VDC power supply
on/off
1
GI
135
163
144
Failure 5V
Failure of internal 5 VDC power supply
on/off
1
GI
135
164
145
Failure 0V
Failure of internal 0 VDC power supply
on/off
1
GI
135
165
150
Failure I/O
Failure in I/O module
on/off
1
GI
135
170
154
Fail. TripRel
Supervision trip circuit
on/off
1
CA
GI
p
36
www
. ElectricalPartManuals
. com
Содержание SIPROTEC 7SS522 V4.6
Страница 326: ...Maintenance and Repair 310 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 432: ...Appendix 416 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 438: ...Index 422 7SS52 V4 Manual C53000 G1176 C182 34 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...