Appendix
386
7SS52 V4 Manual
C53000-G1176-C182-3
1783
Fault L123
O/C fault detection L1-L2-L3
on
2
60
43
1784
Fault L123E
O/C fault detection L1-L2-L3-E
on
2
60
44
1785
Fault E
O/C fault detection E only
on
2
60
45
1791
O/C Gen.Trip
O/C general trip command
on
OT
2
CA
TA
p
68
1800
I>> Fault
O/C fault detection stage I>>
on
OT
1801
I>> Fault L1
O/C fault detection stage I>> phase L1
OT
2
GI
60
46
1802
I>> Fault L2
O/C fault detection stage I>> phase L2
OT
2
GI
60
47
1803
I>> Fault L3
O/C fault detection stage I>> phase L3
OT
2
GI
60
48
1804
T-I>> expired
O/C time TI>> expired
on
OT
2
60
49
1805
I>> Trip
O/C protection I>> phase trip
OT
2
CA
p
91
1810
I> Fault
O/C fault detection stage I>
on
OT
1811
I> Fault L1
O/C fault detection stage I> phase L1
OT
2
GI
60
50
1812
I> Fault L2
O/C fault detection stage I> phase L2
OT
2
GI
60
51
1813
I> Fault L3
O/C fault detection stage I> phase L3
OT
2
GI
60
52
1814
T-I> expired
O/C time TI> expired
v
OT
2
60
53
1815
I> Trip
O/C protection I> phase trip
OT
2
CA
p
90
1820
Ip Fault
O/C fault detection Ip
on
OT
1821
Ip Fault L1
O/C fault detection Ip phase L1
OT
2
GI
60
54
1822
Ip Fault L2
O/C fault detection Ip phase L2
OT
2
GI
60
55
1823
Ip Fault L3
O/C fault detection Ip phase L3
OT
2
GI
60
56
1824
T-Ip expired
O/C time TIp expired
on
OT
2
60
57
1825
Ip Trip
O/C protection Ip phase trip
OT
2
60
58
1831
IE>> Fault
O/C fault detection IE>> earth
on
OT
2
GI
60
59
1832
T-IE>> expired
O/C time TIE>> expired
on
OT
2
60
60
1833
IE>> Trip
O/C protection IE>> earth trip
OT
2
60
61
1834
IE> Fault
O/C fault detection IE> earth
on
OT
2
GI
60
62
1835
T-IE> expired
O/C time TIE> expired
on
OT
2
60
63
1836
IE> Trip
O/C protection IE> earth trip
OT
2
CA
p
92
1837
IEp Fault
O/C fault detection IEp earth
on
OT
2
GI
60
64
1838
T-IEp expired
O/C time TIEp expired
on
OT
2
60
65
1839
IEp Trip
O/C protection IEp earth trip
OT
2
60
66
7601
>Isolator1on
>Isolator 1 - position closed
on/off
IOT
7602
>Isolator1off
>Isolator 1 - position open
on/off
IOT
7603
>Isolator2on
>Isolator 2 - position closed
on/off
IOT
7604
>Isolator2off
>Isolator 2 - position open
on/off
IOT
7605
>Isolator3on
>Isolator 3 - position closed
on/off
IOT
7606
>Isolator3off
>Isolator 3 - position open
on/off
IOT
7607
>Isolator4on
>Isolator 4 - position closed
on/off
IOT
7608
>Isolator4off
>Isolator 4 - position open
on/off
IOT
7609
>Isolator5on
>Isolator 5 - position closed
on/off
IOT
7610
>Isolator5off
>Isolator 5 - position open
on/off
IOT
7611
>CBF L1
>Circuit breaker failure start phase L1
on
IOT
1
TA
194
70
FNo.
Short Text
Logical Function
Log Buffers
Configurable
in Matrix
IEC 60870-5-103
Eve
n
t Log On/
O
ff
Meas
u
red Val
u
e
Tr
ip
(Faul
t)
Log On/
O
ff
Bi
nar
y
Inp
u
t I
Bi
na
ry
O
utput O
(L
E
D
, al
ar
m re
la
y
)
Tr
ip R
e
la
y
T
Data
Unit
Com
p
atibl
e
Annunci
a
ti
on
G
e
n
e
ra
l I
n
te
rr
ogation
Ann
unc. for
Faul
t
Rec
. Buffer
(Tagged)
Type (p: C
o
rrespond
s
t
o
param
e
ter “Function
type“)
In
fo
rma
tio
n
Num
b
e
r
www
. ElectricalPartManuals
. com
Содержание SIPROTEC 7SS522 V4.6
Страница 326: ...Maintenance and Repair 310 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 432: ...Appendix 416 7SS52 V4 Manual C53000 G1176 C182 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 438: ...Index 422 7SS52 V4 Manual C53000 G1176 C182 34 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...