Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
357
Appendix
A
A.1
New and extended functions
Table A- 1
New functions and function changes in Firmware 4.7 SP3
Function
SINAMICS
G120
G120D
1
PM240-2 Power Modules, frame sizes FSD and FSE are sup-
ported
-
-
✓
✓
✓
✓
-
-
-
The Safety Integrated basic function Safe Torque Off (STO) is
supported via the terminals of the PM240-2 Power Module,
frame sizes FSD and FSE
-
-
-
-
✓
✓
-
-
-
2
Revised PM230 Power Module with new Article numbers sup-
ported:
•
IP55 degree of protection: 6SL3223-0DE . . - . . G .
•
IP20 degree of protection and Push Through: 6SL321 . -
1NE . . - . . G .
-
-
✓
✓
✓
-
-
-
-
The Safety Integrated basic function Safe Torque Off (STO) is
supported with the revised PM230 Power Module
-
-
-
-
✓
-
-
-
-
3
PM330 Power Module, frame size HX is supported
-
-
✓
-
-
-
-
-
-
4
1FP1 reluctance motors are supported
-
-
✓
-
-
-
-
-
-
5
Encoderless 1FK7 synchronous motors are supported
-
✓
-
✓
✓
✓
✓
1)
-
-
6
Encoderless 1FG1 geared synchronous motors are supported
-
✓
-
✓
✓
✓
✓
-
-
7
SINAMICS “Standard Drive Control” and “Dynamic Drive Con-
trol” application classes to simplify commissioning and increase
the degree of ruggedness of the closed-loop motor control.
SINAMICS application classes are only available with PM240,
PM240-2 and PM330 Power Modules.
-
✓
✓
✓
✓
✓
-
-
-
8
Moment of inertia estimator with moment of inertia precontrol to
optimize the speed controller in operation
✓
✓
-
✓
✓
✓
✓
✓
✓
9
Friction torque characteristic with automatic plotting to optimize
the speed controller
✓
✓
-
✓
✓
✓
✓
✓
✓
10 Automatic optimization of the technology controller
-
-
✓
✓
✓
-
-
-
-
11 The sign of the system deviation for the additional, free tech-
nology controller can be switched over.
A new parameter defines the sign of the system deviation
matching the particular application, e.g. for cooling or heating
applications.
-
-
✓
-
-
-
-
-
-