Installation
4.2 Electrical Installation
Converter with control units CU250D-2
34
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
4.2.3
Overview of the interfaces
Interfaces of the converter
①
Digital inputs 0 … 5 with status LED
⑧
HTL Encoder connection
②
Fieldbus IN and OUT (PROFINET or
PROFIBUS)
⑨
SSI Encoder connection
③
24 V DC supply IN and OUT
⑩
Slot for a memory card at rear of the Control
Unit
④
Optical interface for operator panel IOP
handheld
⑪
PROFINET status LED
⑤
Converter status LED
⑫
PE grounding terminal
⑥
USB PC connection, address and bus termi-
nation switch for PROFIBUS
⑬
Mains supply connection
⑦
Digital outputs 0 and 1 with status LED
⑭
Motor, brake and temperature sensor con-
nections
Figure 4-4
Interfaces on the converter variants