6/184
Siemens Building Technologies
Basic Dokumentation RVA63.280, RVA53.280
CE1P2374E
Landis & Staefa Division
Summary
19.04.2001
2.51
Clock mode..................................................................................................119
2.52
Winter- / summertime changeover...............................................................120
2.53
Summer- / wintertime changeover ...............................................................120
2.54
Display of PPS communication....................................................................121
Multi-functional inputs ..................................................................................................122
2.55
Input H1 .......................................................................................................122
2.55.1
Changeover of operating mode ...................................................................123
2.55.2
Minimum flow temperature setpoint TVHw ..................................................124
2.55.3
Heat generation lock....................................................................................124
2.55.4
Heat demand DC 0...10 V............................................................................125
2.55.5
Changeover of operating mode ...................................................................125
2.56
Minimum flow temperature setpoint contact H (TVHw) ...............................126
2.57
Maximum value of heat demand signal DC 0...10 V (H1)............................127
2.58
Operating action contact H1 and H2............................................................127
2.59
Input B31/H2................................................................................................128
2.59.1
D.h.w. sensor 2............................................................................................128
2.59.2
Minimum flow temperature setpoint (TVHw)................................................129
2.59.3
Heat generation lock....................................................................................129
2.59.4
Changeover of operating mode ...................................................................129
3
Description of OEM settings ........................................................................130
Heat generating equipment..........................................................................................130
3.1
Minimum limitation of boiler temperature (TKmin
OEM
) ..................................130
3.2
Maximum limitation of boiler temperature (TKmax) .....................................130
3.3
Switching differential of the boiler temperature............................................131
3.3.1
Single-stage burner .....................................................................................132
3.3.2
2-stage burner .............................................................................................132
3.4
Minimum limitation of burner running time ...................................................133
3.5
Release integral of burner stage 2...............................................................134
3.5.1
Temperature-time integral ...........................................................................134
3.6
Reset integral of burner stage 2 ..................................................................135
3.6.1
Temperature-time integral ...........................................................................135
3.7
Pump overrun time ......................................................................................136
3.8
Operating mode of the boiler .......................................................................137
3.8.1
Extended burner running time .....................................................................137
3.9
Protective boiler start-up..............................................................................138
3.9.1
Impact on 2-position loads...........................................................................138
3.9.2
Impact on modulating loads.........................................................................139
3.9.3
Temperature-time integral ...........................................................................140
3.10
Control of boiler pump .................................................................................141
Heating circuit ..............................................................................................................142
3.11
Boost of flow temperature setpoint mixing valve (UEM) ..............................142
3.12
Gain factor of room influence (KORR).........................................................143
3.13
Constant for quick setback and optimum start control (KON)......................144
3.13.1
Quick setback without room influence .........................................................144
3.13.2
Optimum start control without influence.......................................................144
3.14
Boost of room temperature setpoint (DTRSA) .............................................145
3.14.1
Boost heating...............................................................................................145
3.15
Frost protection for the plant........................................................................146
3.15.1
Frost protection for the plant........................................................................146
3.16
Control mode of actuator .............................................................................147
3.17
Switching differential of actuator..................................................................148
3.17.1
Control of mixing valve actuator ..................................................................148
3.18
Overtemperature protection for the pump heating circuit ............................149