Parameterization
05.2003
6SE7087-6JP60
Siemens AG
8-10
Operating Instructions
SIMOVERT MASTERDRIVES
8.3.2.2 Drive
settings
With menu
File
New
...
you can create a new drive for
parameterization (see Fig. 8-5). The system creates a download file
(*.dnl), in which the drive characteristic data (type, software version) are
stored. You can create the download file on the basis of an empty
parameter set or the factory setting.
Fig. 8-5
Creating a new drive
Once you have created a drive, you can start it again with the menu
function
File
Open
for parameterization by opening the download
file. The last four drives can be opened via
"Parameter sets last dealt
with"
.
When you create a new drive, the window "Properties - Drive" (Fig. 8-6)
opens. Here you must enter the following data:
♦
In dropdown list box "Device type", select the type of device (e.g.
MASTERDRIVES VC(Plus)). You can only select the devices
stored.
♦
In dropdown list box "Software version", you can select the software
version of the device. You can generate databases for (new)
software versions that are not listed when you start online
parameterization.
♦
You must only specify the bus address of the drive during online
operation (switchover with button Online/Offline)
The specified bus address must be the same as that of the
parameterized SST bus address in SIMOVERT MASTERDRIVES
(P700).