Installation
05.2003
6SE7087-6JP60
Siemens AG
5-8
Operating Instructions
SIMOVERT MASTERDRIVES
♦
Remove the cover of the selected slot on the front panel.
♦
To do so, you must carefully cut through the four connecting points
of the cover on the front panel with a thin knife.
♦
Undo the two optional board screws by about one turn each.
♦
Loosen the connection between the system connector and the
board so as to prevent any mechanical tension arising when the
screws are fully unscrewed.
♦
Take out the optional board screws and remove the board.
Optional boards can only be inserted in slot A and slot B. Slot C of the
unit is permanently pre-assigned for the terminal module EBV.
♦
Insert the optional board from the behind the broken-out slot conver
(
) until the position of the 64-pole system connector on the
electronic board corresponds with the position of the socket.
♦
Insert the option board into the 64-pole system connector on the
electronic board (
).
♦
Screw the optional board tight at the fastening points in the front
section of the optional board with the two screws (
).
Slot C
Slot C
Slot B
Slot B
Slot A
Fig. 5-7
Installing the optional board
Removing the slot
cover
Removing the
optional board
Mounting the
optional board
NOTICE