Explanation of the parameters
Parameters
87_
Fieldbus parameter settings (refer to the MOVITRAC
®
07 Communication manual for more information)
P870 ... P872 can be used for defining the contents of process output data words PO1 ... PO3. This definition is neces-
sary so MOVITRAC
®
07 can allocate the appropriate setpoints.
The following process output assignments are available:
NO FUNCTION:
The content of the process output data word is ignored.
SPEED:
Speed setpoint selection in rpm.
MAX. SPEED:
Maximum speed (P302).
RAMP:
Ramp time for setpoint selection (P130 / P131).
CTRL. WORD 1:
Control signals for start/stop, etc.
SPEED [%]:
Selection of a speed setpoint in % of 3000 rpm.
PI CTRL [%]:
PI controller setpoint
870
Setpoint description PO1
Factory setting: CTRL. WORD 1
871
Setpoint description PO2
Factory setting: SPEED
872
Setpoint description PO3
Factory setting: NO FUNCTION
P873 ... P875 can be used for defining the contents of process input data words PI1 ... PI3. This definition is necessary
so MOVITRAC
®
07 can allocate the appropriate actual values.
The following process input assignments are available:
NO FUNCTION:
The content of the process input data word is 0000
hex
SPEED:
Current actual speed in rpm.
ACTIVE CURR.:
Momentary active current of the inverter in % of I
N
.
OUTP.CURRENT: Momentary
output
current of the inverter in % of I
N
.
STATUS WORD1:
Status information of the inverter.
SPEED [%]:
Momentary actual speed value in % of 3000 rpm.
IPOS PI-DATA:
IPOS process input data.
PI CTRL [%]:
Actual values of the PI-controller.
873
Actual value description PI2
Factory setting: STATUS WORD1
874
Actual value description PI2
Factory setting: SPEED
875
Actual value description PI3
Factory setting: OUTPUT CURRENT
876
PO data enable
OFF
The process output data which were most recently valid remain in effect.
ON
The process output data sent most recently by the fieldbus controller
come into effect.
9__
IPOS/LOGODRIVE parameters
93_
IPOS/LOGODRIVE special functions
Parameters P931 and P932 are only relevant for LOGODrive units.
931
•
Task 1/2
on / ON
Task 1 and task 2 are running.
off / OFF
Task 1 and task 2 are stopped.
932
Task 2 (display only)
on / ON
Task 2 is running.
off / OFF
Task 2 is stopped.
No.
OP Name
Description
P6..
P60.
P600