![SEW-Eurodrive MOVITRAC 07 Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/sew-eurodrive/movitrac-07/movitrac-07_system-manual_1250133152.webp)
9
152
System Manual – MOVITRAC® 07
Parameter list
Startup
11_
Analog input 1 (+10 V)
110
•
8463
AI1 scaling
0.1 ... 1 ... 10
112
•
8465
AI1 operation
mode
0
1
5
6
3000 rpm (0 – 10 V)
N-MAX (0 – 10 V)
N-MAX (0 – 20 mA)
N-MAX (4 – 20 mA)
12_
Analog input 2 (setpoint potentiometer of the integrated operating panel)
121
•
8811
Addition Setpoint
Potentiom.
0
1
2
OFF
ON
ON EXCEPT FSP
122
•
8799
Local Potentiom-
eter Mode
0
1
2
UNIPOL. CW
UNIPOL. CCW
BIPOL.CW+CCW
13_
Speed ramps
130
•
8807
Ramp t11 UP
0.1 ... 2 ... 2000 [s]
131
•
8808
Ramp t11 DOWN
0.1 ... 2 ... 2000 [s]
136
•
8476
Stop ramp t13
0.1 ... 2 ... 20 [s]
138
8794
Ramp limit
0
1
NO
YES
15_
Motorized potentiometer
150
•
8809
Ramp t3 UP
0.2 ... 20 ... 50 [s]
152
•
8488
Save last set-
point
off
on
OFF
ON
16_
Fixed setpoints (set 1)
160
•
8489
Internal setpoint
n11
0 ... 150 ... 5000 [rpm]
161
•
8490
Internal setpoint
n12
0 ... 750 ... 5000 [rpm]
162
•
8491
Internal setpoint
n13
0 ... 1500 ... 5000 [rpm]
163
•
8814
Internal setpoint
n11 PI-controller
0 ... 3 ... 100 [% I
N
]
164
•
8815
Internal setpoint
n12 PI-controller
0 ... 15 ... 100 [% I
N
]
165
•
8816
Internal setpoint
n13 PI-controller
0 ... 30 ... 100 [% I
N
]
No.
OP Index
dec.
Name
Range / factory setting
Value after startup
Display
MOVITOOLS
n11
n12
0
0
I
Содержание MOVITRAC 07
Страница 1: ...MOVITRAC 07 Edition 02 2003 System Manual 1056 2915 EN...
Страница 2: ...SEW EURODRIVE...
Страница 6: ...6 System Manual MOVITRAC 07 Contents...
Страница 165: ...MOVITRAC 07 Edition 12 2003 Addendum to the System Manual 11254114 EN...