Manual speed control module and external setpoint selection
Startup
Fault indication
If a fault occurs, the display changes to the
symbol and it shows the flashing fault
code, e.g.
F-11
(fault list in Sec. Operation and servicing).
Warnings
Some parameters are not allowed to be altered in all operating states. If you try to do so,
the following display appears:
r-19
...
r-32
. The display shows a code corresponding
to the particular action, e.g.
r-28
(controller inhibit necessary). See Sec. Operation and
servicing for a list of warnings.
9.5
Manual speed control module and external setpoint selection
Manual speed control module of the operating panel (local manual operation): LED
flashes
External setpoint selection
Control via:
– Terminals
– Serial interface
– Setpoint potentiometer on AI11/AI12
Manual speed control module
The only relevant parameters in "manual speed control module" operating mode are:
•
P122 Local Potentiometer Mode
•
"RUN" and "STOP/RESET" buttons
•
Setpoint potentiometer
LEDs
and
flash when the manual speed control module is activated.
rpm
03158BXX
Figure 81: Manual setpoint adjustment (2x = double-click)
rpm
0
0
I