![SEW-Eurodrive MOVITRAC 07 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/sew-eurodrive/movitrac-07/movitrac-07_system-manual_1250133074.webp)
4
74
System Manual – MOVITRAC® 07
Explanation of the parameters
Parameters
4__
Reference signals
The following reference values are used for recording and signaling certain operational states. All signals in parameter
group 4__ can be output via binary outputs.
The signals are valid if the inverter has signaled
ready after switch-on and there is no fault display.
40_
Speed reference signal
The inverter outputs the "1" signal at P403 if the speed is less than or greater than the set reference speed.
Speed reference signal
400
•
Speed reference value
Setting range 0 ... 750 ... 5000 [rpm]
401
•
Hysteresis
Setting range 0 ... 100 ... 500 [rpm]
402
•
Delay time
Setting range 0 ... 1 ... 9 [s]
403
•
Signal = "1" if:
0 / n < n
ref
1 / n > n
ref
45_
PI controller ref signal (see Sec. Project Planning / PI-controller / Reference signal)
These parameters determine whether and how the PI reference signal is triggered
450
•
PI actual value reference
0.0 ... 100.0 [%]
451
•
Signal = "1" if:
0 / PI-Act. < PI-Ref
1 / PI-Act. > PI-Ref
No.
OP Name
Description
P6..
P60.
P600
Содержание MOVITRAC 07