9
154
System Manual – MOVITRAC® 07
Parameter list
Startup
4__
Reference signals
40_
Speed reference signal
400
•
8539
Speed reference
value
0 ... 750 ... 5000 [rpm]
401
•
8540
Hysteresis
0 ... 100 ... +500 [rpm]
402
•
8541
Delay time
0 ... 1 ... 9 [s]
403
•
8542
Signal = "1" if:
0
1
n < n
ref
n > n
ref
45_
PI controller ref signal
450
•
8813
PI actual value
reference
0.0 ... 100.0 [%]
451
•
8796
Signal = "1" if:
0
1
PI actual value < PI reference
PI actual value > PI reference
5__
Monitoring functions
50_
Speed monitoring
500
•
8557
Speed monitor-
ing
0
3
OFF
MOT. & REGEN.MODE
501
•
8558
Delay time
0 ... 1 ... 10 [s]
6__
Terminal assignment
60_
Binary inputs
60-
•
8803
Binary inputs
DI01 has a fixed
setting of
CW/STOP.
0
1
2
3
4
5
6
7
8
-
DI02
DI03
DI04
DI05
CCW/STOP
FIX SETPT SW.OVn11/n21
n12/n22
CCW/STOP
ENABLE
n11/n21
n12/n22
CCW/STOP
ENABLE
MOT. POT UP
MOT. POT DN
ENABLE
FIX SETPT SW.OVn11/n21
n12/n22
CCW/STOP
SETPOINT HOLDn11/n21
n12/n22
CCW/STOP
ENABLE
EXT. FAULT
ERR. RESET
CCW/STOP
ENABLE
FAULT RESET
TF RESP.
CCW/STOP
EXT. FAULT
n11/n21
n12/n22
CCW/STOP
ENABLE
n11/n21
CTRL.INHIBIT
(Deviating combination set with MOVITOOLS)
601
8336
Binary input DI02
NO FUNCTION
ENABLE
/STOP
CW/STOP
CCW/STOP
n11/n21
n12/n22
FIXED SETP. SELECT
MOTOR POT UP
MOTOR POT DOWN
/EXT. FAULT
FAULT RESET
SETPOINT HOLD
TF RESPONSE (only with DI05)
CONTROL.INHIBIT
602
8337
Binary input DI03
603
8338
Binary input DI04
604
8339
Binary input DI05
No.
OP Index
dec.
Name
Range / factory setting
Value after startup
Display
MOVITOOLS
0
0
I