Manual – IPOSplus®
373
24
"Table positioning" sample program
Assembler – Examples
A "1" signal at output DO15 "Table position valid" indicates that the selected table posi-
tion has been reached. This output is reset once a new table position is selected. By ad-
ditionally evaluating output DO16 "IPOS in position", it is also possible to detect when
the selected table position is exited even when the controller is deactivated ("Controller
inhibit" = "0").
The drive is moved away from a hardware limit switch by entering a "1" signal at the
RESET input (DI02).
24.4.2 Settings
The detailed configuration of the inputs/outputs (see below) and the variables used in
the program is documented in the remark section of the program source code.
The table positions can be written via the variable window of the Assembler or with the
keypad in the variables (H00 ... H15). The variables are stored in the non-volatile mem-
ory.
INFORMATION
The user travel units numerator and denominator in the position window header are
not relevant here because the position values of travel variables are always evaluated
in increments (4096 increments/motor revolution).