140
Manual – IPOSplus®
12
P96x IPOSplus
®
modulo function
P9xx IPOS Parameters
Sets the baud rate of the connected CAN encoder.
12.7 P96x IPOS
plus
®
modulo function
The IPOS
plus®
modulo function is used for endless positioning, for example with circular
indexing tables or chain conveyors. Refer to the IPOS
plus®
manual for detailed informa-
tion.
12.7.1 P960 Modulo function
Setting range: OFF / SHORT / CW / CCW
• OFF: The modulo function is deactivated.
• SHORT: The "short travel" modulo function is active. The drive moves from the actual
position to the target position taking the shortest possible route. Both directions of
rotation are possible.
• CW: The "CW" modulo function is active. The drives moves from its actual position
to the target position with a "CW" direction of rotation, even if this means moving a
longer distance. The "CCW" direction of rotation is not possible.
• CCW: The "CCW" modulo function is active. The drives moves from its actual
position to the target position with a "CCW" direction of rotation, even if this means
moving a longer distance. The "CW" direction of rotation is not possible.
12.7.2 P961 Modulo numerator
Setting range: 0 – 1 – 2
31
– 1
Simulation of the gear unit by entering the number of teeth of the gear unit and the ad-
ditional gear.
Modulo numerator = Numerator gear unit i x numerator additional gear i
12.7.3 P962 Modulo denominator
Setting range: 0 – 1 – 2
31
– 1
Simulation of the gear unit by entering the number of teeth of the gear unit and the ad-
ditional gear.
Modulo denominator = Denominator gear unit i x denominator additional gear i
12.7.4 P963 Modulo encoder resolution
Setting range: 0 – 4096 – 65535
Resolution of the selected IPOS
plus®
encoder system in increments.
The IPOS
plus®
encoder resolution for positioning to the motor encoder will be set to
4,096 increments (prerequisite is an encoder resolution of 512 to 2,048).
P
i
f
kVA
Hz
n