24
"Hoist" sample program
Assembler – Examples
24.2.5 Setting parameters relevant to the example
24.2.6 Calculating the IPOS
plus
®
parameters
SW limit switch
see schematic structure
Travel distance
factor numerator
The travel dimension unit should be set to mm!
Number of increments per revolution of the drive wheel
Incr./motor rev. × gear ratio
4096 incr. × 5 = 20480
20480 × 100 (expansion factor) = 2048000
Group
Parameter
Setting
30_ Limits
P302 Maximum speed 1 [rpm]
P350 Change direction of rotation
1500
OFF
60_ Binary inputs basic unit
P600 Binary input DI01
P601 Binary input DI02
P602 Binary input DI03
P603 Binary input DI04
P604 Binary input DI05
ENABLE/STOP
RESET
REFERENCE CAM
/LS CW
/LS CCW
61_ Binary inputs DIO11 option
P610 Binary input DI10
...
P617 Binary input DI17
IPOS INPUT
...
IPOS INPUT
63_ Binary outputs DIO11 option
P630 Binary output DO10
P636 Binary output DO16
P637 Binary output DO17
/FAULT
IPOS IN POSITION
IPOS REFERENCE
7__ Control functions
P700 Operating mode
P730 Brake function
CFC & IPOS
YES
9__ IPOS Parameter
P900 Reference offset [mm]
P901 Reference speed 1 [rpm]
P902 Reference speed 2 [rpm]
P903 Reference travel type
P910 Gain X controller
P911 Positioning ramp 1 [s]
P912 Positioning ramp 2 [s]
P913 Positioning speed CW [rpm]
P914 Positioning speed CCW [rpm]
P915 Velocity precontrol [%]
P916 Ramp type
P920 SW limit switch CW [mm]
P921 SW limit switch CCW [mm]
P922 Positioning window [inc]
P923 Lag error window [inc]
P930 Override
500
200
50
1
2.8
1
1
1350
1350
100
SINE
2100
-100
50
5000
OFF
Travel distance factor NUMERA-
TOR/DENOMINATOR
Travel distance factor NUMERATOR
Travel distance factor DENOMINATOR
Unit
2048000
15708
mm
P
i
f
kVA
Hz
n
P
i
f
kVA
Hz
n