Set commands
Assembler – Commands
23.8.3 Set commands variable SET / fault response SETFR / Indirect addressing SETI / Interrupt
SETINT / system values SETSYS
SET
The SET command loads argument X1 with the content of argument X2 (variable H or
constant K). The result is written to argument X1, argument X2 remains unchanged.
Structure
SETFR/SET
FAULT REACTION
The SETFR command defines the response to a unit fault. The fault code is entered in
argument X1 of the command. The reaction to the unit fault is selected with argument 2.
The selected fault reaction will only be executed once the SETFR command has been
processed. The
most recently
selected fault response (call of the SETFR command or
changes in P83_ "Fault response") is the one in effect.
You can program all responses to a fault as long as it has a point in column "P" in the
fault list in the operating instructions or the system manual.
Example:
• Fault 27 "Limit switches missing", no point in column P: Cannot be programmed
• Fault 28 "Fieldbus timeout", point in column P: programmable
Command structure
Mxxx SET X1 = X2
Mxxx: Label
(optional)
X1:
Hxxx = Result of the statement.
X2:
Hyyy = Source.