SMD 989
– User Manual
Page 82 (105)
BAY 1: TS ERRORS
1.4)
CONTINUITY COUNT ERROR
THRESHOLD: .001 ERRORS/SEC
1.5a) PMT ERROR
THRESHOLD: 00500 ms
BAY 1: TS ERRORS
1.6)
ES PID ERROR
THRESHOLD: 00500 ms
NULL PACKET ERROR
THRESHOLD: 20%
the value entered. Can be set from1 to 999 errors per second. Default is 1 error per
second.
-
PMT Error (1.5a):
an error will be indicated when the PMT is not present for a period
exceeding the time entered (in ms). Can be
set from 100ms to 10000ms. Default is
500ms.
-
ES PID Error (1.6):
an error will be indicated
when an Elementary Stream (ES) is not
present for a period exceeding the time
entered (in ms). Can be set from 100ms to
10000ms. Default is 500ms. The modulator will automatically detect up to 400
elementary stream PIDs on both the primary
and backup transport streams.
-
Null Packet Ratio:
an error is indicated when
the ratio of the number of null packets in
comparison to the normal video packets
every second exceeds the value entered
.