AC Power
–
Operating Voltage:
95-135 VAC or 180-265 VAC
Current Draw/Power:
200 Watts
Frequency:
47-63Hz
Line Cord:
Detachable, 3-prong
General
–
RoHS Compliant:
Yes
Operating Temperature:
0 to 45 degrees C
Operating Humidity:
<95% Non-Condensing
Cooling:
Forced air, front intake, rear exhaust
Temperature monitor:
Fan failure, internal temperature sensor
Size:
Height = 1RU (13/4”), Width = 19”, Depth = 19”
19 in. rack mountable, removable ears
Rack clips and screws included
Weight:
~9.5 lbs. (base unit)
~12.75 lbs. (Fully Loaded)
Pollution Degree:
2
Installation Category:
II
Grounding Post:
On chassis
Grounding Thread Size:
8/32”
SMD 952 Dual Redundant AC Power Supply
– Option
Operating Voltage:
95-135 VAC or 180-265 VAC
Current Draw:
275 Watts
Frequency:
47-63Hz
Line Cord:
Detachable, 3-prong
Redundancy
Dual Hot Swappable Load Sharing
SMD 954 Dual Redundant DC Power Supply
– Option
Operating Voltage:
-40 to -72VDC, Normal -48VDC
Current Draw:
250 Watts
Frequency:
0Hz
Connection:
Screw Terminal, -48VDC and 0VDC
Redundancy
Dual Hot Swappable Load Sharing
SMD 910 Single Stream Modulator
General
–
RoHS Compliant:
Yes
ASI Serial TS Input
–
Connector:
(4) BNC, female
Impedance:
75 ohms
Standard:
ETSI EN 50083-9 DVB ASI
Data Bit Rate:
270 Mbps
Packet Size:
188 or 204 byte support
Transmission Mode:
Burst and packet mode support
Min TS Rate Supported:
0.5 Mbps
Max TS Rate Supported:
160 Mbps
Specifications are subject to change without notice.