SMD 989
– User Manual
Page 44 (105)
Configure Modulator - BISS
Configure BISS Scrambling (SMD 971 Option)
The BISS Scrambling is configured by selecting
the BISS tab in the Configuration Modulator window. When BISS Scrambling is enabled the entire
transport stream will be scrambled. A CA_descriptor will be added to the PMT and CAT table will
be created if one does not exist. If a CAT table does exist it will be altered.
Scrambling:
Enabled/Disabled:
When set to Enabled the BISS encryption feature becomes active and is
ready for the entry of either the Mode 1 or Mode E session word/ID. When Disabled no BISS
encryption is added to the stream.
.
Figure 37 BISS Scrambling configuration
BISS Mode 1
: Permits entry of an encrypted twelve (12) character hex session word.
BISS Mode E:
Permits entry of an encrypted sixteen (16) character hex session word along with
a 14 character hex Injected ID. In BISS Mode E the session word is encrypted and cannot be
viewed from the front panel or any remote interface.