SMD 989
– User Manual
Page 67 (105)
sensor3VMinLimit.0 - 3.10 VDC
sensor3VMaxLimit.0 - 3.50 VDC
5 Volt Controller Supply
sensor5VMinLimit.0 - 4.70 VDC
sensor5VMaxLimit.0 - 5.30 VDC
12 Volt Controller Supply
sensor12VMinLimit.0 - 11.28 VDC
sensor12VMaxLimit.0 - 12.72 VDC
Unit Temperature
sensorTempMinLimit.0 - 0 C
sensorTempMaxLimit.0 - 45.00 C
The Events tab allows the setup of Events reporting and actions. Events are notable status
changes in the SMD 989. Click the + icon to expand the event configuration options. The
Selection Options popup menu allows easier configuration of the selected event. Refer to Figure
77. Event Descriptions.
Name
Description of Event
10MHz Ext. Ref Clock Change
Indicates the external reference clock was not present
Date/Time Change
The unit’s date/time has been changed
NTP Update
The unit’s date/time was updated by the NTP server
Software Update Failed
The software update did NOT complete successfully
Software Update Succeeded
The software update completed successfully
Unit Booted
The unit has been started
Unit Shutdown
The unit was shutdown
Figure 77: Event descriptions
Figure 76: Event Configuration