Section 3: COOLING INSTALLATION
16)
Thermal Valve should always be in full CW position.
17)
The reservoir may now be disconnected from the cooling circuit by removing the hoses at the
glycol service ports.
3.5 Connecting Seawater to Heat Exchanger
1)
Connect seawater from installer supplied pump to ½” (12.5 mm) hose barb on gyro side of heat
exchanger. Use the same practices as other below waterline seawater plumbing. Required flow
rate is 2 GPM (8 LPM) or greater.
2)
Connect seawater discharge to overboard drain. Use the same practices as other below
waterline seawater plumbing.