INSTALLATION
MANUAL
Product:
Document
#:
Rev:
Page:
MODEL
7000A
GYRO
90051
3
9
of
16
Section
2:
ELECTRICAL
INSTALLATION
3.
ALARM
OUTPUT
CONNECTION
INSTRUCTIONS
Do
not
connect
J9
to
voltage
over
30VDC
or
damage
may
result.
Do
not
connect
J9
to
AC
voltage
or
damage
may
result.
a.
The
Alarm
output
is
one
of
2
switched
output
signals
at
receptacle
J9.
This
connector
is
shared
with
the
Seawater
Pump
Control
output.
b.
The
Alarm
output
is
volts
‐
free
or
dry
contacts,
meaning
a
control
voltage
must
be
connected
to
activate
whatever
alarm
circuit
is
used.
c.
The
Alarm
output
should
go
to
the
boat’s
Alarm
&
Monitoring
System
or
a
suitable
audible
and
visual
alarm.
Suggested
wiring
is
shown
in
Figure
11.
d.
The
Alarm
output
logic
is:
open
contacts
=
Alarm
or
power
is
off
4.
SEAWATER
PUMP
CONTROL
CONNECTION
INSTRUCTIONS
The
seawater
pump
power
must
be
on
a
separate
circuit
breaker
from
the
Gyro
Control
Box
24VDC
breaker
and
the
Motor
Drive
J
‐
Box
230VAC
breaker.
Do
not
connect
J9
to
voltage
over
30VDC
or
damage
may
result.
Do
not
connect
J9
to
AC
voltage,
or
damage
may
result.
a.
The
Seawater
Pump
Control
output
is
the
other
of
2
switched
output
signals
at
receptacle
J9.
This
connector
is
shared
with
the
Alarm
output.
b.
The
Seawater
Pump
Control
output
is
volts
‐
free
or
dry
contacts,
meaning
a
control
voltage
must
be
connected
to
activate
the
Seawater
Pump
relay.
c.
The
Seawater
Pump
Control
output
should
go
to
a
relay
to
control
the
Seawater
Pump
according
to
Figure
11.
d.
The
Seawater
Pump
Control
output
logic
is:
closed
contacts
=
Seawater
Pump
On.