МТ-700 fleet tracking system
78
Figure 81. Digital output parameters
Using the «Digital value» the following parameters can be configured: (
ON
– activates the output (after the command execution).
OFF
– deactivates the output (after the command execution).
Pulse length
– if specified, the output will be active for the specified time. If the value is
«0» then the output will be activated on the next “ON” command.
Digital outputs
can be set
using the SMS-command
Setport
with the following
parameters:
Example:
setport 6,1
Terminal response :
id(setport): OK
Indication on
Р
6-
Р
7 ports
The tracker possesses a wide range of self-diagnostics instruments(including event log,
debug journal, and state indication on the digital output).
For indication of the malfunction the external indicator can be connected on the output.
Figure 82. State indication
In order to achieve that «Current state indication» it should be configured on one of the
P6, P7 ports (
). Two functions can be activated:
Sensors «Status Flag» and «error word» are send to the server.
If any error occurs, then the output is activated.
Port value send to server is a bitwise error word, which can be used to decoded, if
needed.
Drive style on the
Р6
-
Р
7 ports
«Drive Style» sensors are used for speed controlling, sharp acceleration and high
deceleration of the vehicle.
The tracker should be properly mounted to the vehicle’s body. The linear calibration
and horizon establishment should be conducted.
Содержание MT-700 ENT
Страница 1: ...www scout gps ru МТ 700 Fleet monitoring system Operation manual Version 1 0 ...
Страница 116: ...МТ 700 fleet tracking system 116 Frequency fuel level sensor Figure 4 Frequency fuel level sensor ...
Страница 117: ...МТ 700 fleet tracking system 117 Digital LLS fuel level sensor Figure 5 digital LLS fuel level sensor ...
Страница 118: ...МТ 700 fleet tracking system 118 Buzzer connection Figure 6 Buzzer connection ...
Страница 119: ...МТ 700 fleet tracking system 119 J1708 and CANJ1939 connection Figure 7 J1708 and CAN J1939 connection ...
Страница 120: ...МТ 700 fleet tracking system 120 Engine speed sensor connection Figure 8 Engine speed sensor connection ...
Страница 121: ...МТ 700 fleet tracking system 121 iButton Figure 9 iButton connection Minus to the common wire data to the P3 ...
Страница 124: ...МТ 700 fleet tracking system 124 available 124 ...
Страница 130: ...МТ 700 fleet tracking system 130 ...
Страница 133: ...МТ 700 fleet tracking system 133 calibration reset Error impossible ...
Страница 138: ...МТ 700 fleet tracking system 138 ...
Страница 139: ...МТ 700 fleet tracking system 139 Linear calibration Statistics reset ...
Страница 141: ...МТ 700 fleet tracking system 141 ID CheckCalibration ...
Страница 143: ...МТ 700 fleet tracking system 143 ...
Страница 144: ...МТ 700 fleet tracking system 144 Horizon horizon no ОК Horizon ID horizon OK set ID testmemory Processing ...
Страница 146: ...МТ 700 fleet tracking system 146 132 ...
Страница 149: ...МТ 700 fleet tracking system 149 133 ...
Страница 152: ...МТ 700 fleet tracking system 152 Autohorizon AutoHorizon setting no ОК AutoHorizon id AutoHorizon OK enable ...
Страница 154: ...МТ 700 fleet tracking system 154 Location track cell php hex 0 mcc 250 mnc 99 lac 14756 cid 10212 ...
Страница 155: ...МТ 700 fleet tracking system 155 ...