Digital inputs P0-P5 setting
Digital inputs are intended to connect logic sensors, which operate in two different states
– on and off, which correspond accordingly to high and low voltage levels. Such sensors are:
“Ignition state”, “Panic button”, movement sensor and others.
Figure 63. Digital input parameters
Available sensors are: («Digital value», «Ignition», «Battery disconnect switch», «panic
button») they only differ by the icon picture in the PORTS tab. The settings are identical
Digital input has the following parameters:
Ports P0-P1:
Figure 64.
Ports P0-P5:
Debounce timeout (мс)
– minimal pulse length, which can be fixated. The parameter is
used to protect against false actuation.
Recommended value – 1000, for the panic button – 100.
Invert the signal
– Inverts the logic of work. By default, the High voltage on the input
corresponds to a value “1”. After inverting the “1” is corresponding to a low level of signal.
Ignition filtering–
if the parameter is on, all of the sensor’s changes are not counted until
the ignition is “ON”.
Содержание MT-700 ENT
Страница 1: ...www scout gps ru МТ 700 Fleet monitoring system Operation manual Version 1 0 ...
Страница 116: ...МТ 700 fleet tracking system 116 Frequency fuel level sensor Figure 4 Frequency fuel level sensor ...
Страница 117: ...МТ 700 fleet tracking system 117 Digital LLS fuel level sensor Figure 5 digital LLS fuel level sensor ...
Страница 118: ...МТ 700 fleet tracking system 118 Buzzer connection Figure 6 Buzzer connection ...
Страница 119: ...МТ 700 fleet tracking system 119 J1708 and CANJ1939 connection Figure 7 J1708 and CAN J1939 connection ...
Страница 120: ...МТ 700 fleet tracking system 120 Engine speed sensor connection Figure 8 Engine speed sensor connection ...
Страница 121: ...МТ 700 fleet tracking system 121 iButton Figure 9 iButton connection Minus to the common wire data to the P3 ...
Страница 124: ...МТ 700 fleet tracking system 124 available 124 ...
Страница 130: ...МТ 700 fleet tracking system 130 ...
Страница 133: ...МТ 700 fleet tracking system 133 calibration reset Error impossible ...
Страница 138: ...МТ 700 fleet tracking system 138 ...
Страница 139: ...МТ 700 fleet tracking system 139 Linear calibration Statistics reset ...
Страница 141: ...МТ 700 fleet tracking system 141 ID CheckCalibration ...
Страница 143: ...МТ 700 fleet tracking system 143 ...
Страница 144: ...МТ 700 fleet tracking system 144 Horizon horizon no ОК Horizon ID horizon OK set ID testmemory Processing ...
Страница 146: ...МТ 700 fleet tracking system 146 132 ...
Страница 149: ...МТ 700 fleet tracking system 149 133 ...
Страница 152: ...МТ 700 fleet tracking system 152 Autohorizon AutoHorizon setting no ОК AutoHorizon id AutoHorizon OK enable ...
Страница 154: ...МТ 700 fleet tracking system 154 Location track cell php hex 0 mcc 250 mnc 99 lac 14756 cid 10212 ...
Страница 155: ...МТ 700 fleet tracking system 155 ...