Installation and adjustment
FM 240 MuW Beta Type S Rev.01
2010-09-15
23
1
Inductive limit switch
2
Switching cam
Key
3
Band marking safety zone
Figure 5: Inductive limit switches
The limit switches must switch so that the carriage comes to a stop
immediately before the safety zone. The safety zone is factory-marked
on the unit by a band (3).
Procedure
1.
Connect the power to the limit switches.
2.
Slacken the limit switch fixing screws.
3.
Run the carriage as far as the braking position.
4.
Move the limit switch (NC contact) under the switching cam until it
trips and the LED on the sensor goes out.
5.
Move the carriage away.
6.
Tighten the limit switch.
7.
Check the correct position of the limit switch: Move the carriage
manually and observe the switching operation.
8.
Fit the limit switch array covering.