Installation and adjustment
20
2010-09-15
FM 239 MuW Beta Type Z Rev.01
6
Installation and adjustment
The linear unit can be attached by the following methods:
•
On mounting rails
•
By screws inserted into the sliding blocks
•
By screws inserted into the factory-fitted tapped hole rails
E
Install the linear unit on a flat surface. Unit parallelism < 0.2
mm/1,000 mm.
E
Mounting by the rails with tapped holes in them is the preferable
solution:
for highly dynamic applications;
where the linear unit has only two attachment points.
6.1
Installing the linear unit by mounting rails
Figure 3: Mounting rails (1)
E
The recommended maximum spacing between the mounting rails is
700 mm.
Procedure
1.
Attach the mounting rails (1) loosely in position (figure 2).
2.
Align the linear unit axially.
3.
Tighten the mounting rails (1)
(for tightening torques see section 3).