Section 3: Operation and Configuration
Page 3-40
CW408 Operator Manual
3.16 SERVICE MODE (Cont’d)
SENSOR ADJUST MODE
Menu
Description
Test print is in progress
Press the
FEED
button to start printing.
Press the
FEED
button while printing to pause the test print operation. Press
the
FEED
button again to continue printing.
To exit the Test print mode
Make sure that the printer is in pause mode, press the
power button to set
printer to off.
Displays the current voltage of I-mark sensor on the upper part of the display.
Adjust the light emission level of I-mark sensor with the
LINE
button. This off-
set determines how soon the sensor will respond to an incoming I-mark.
The adjustment range is between 00 to 03 and is shown on the bottom line of
the display. The initial setting is 02.
Press the
FEED
button to save the setting and move to the next screen.
Displays the current voltage of I-mark sensor on the upper part of the display.
Adjust the light reception level of I-mark sensor with the
LINE
button. This off-
set determines how soon the sensor will respond to an incoming I-mark.
The adjustment range is between 00 to 15 and is shown on the bottom line of
the display. The initial setting is 07.
Press the
FEED
button to save the setting and move to the next screen.
Displays the current voltage of I-mark sensor on the upper part of the display.
The slice level is calculated automatically and displayed on the bottom line.
You can also adjust the slice level by pressing the
LINE
button.
The input range is 0.0V, and from 0.3V to 2.9V (adjustable in increments of
0.1V). The initial setting is 1.4V.
Notes
:
•
The slice level is automatically set by firmware when the value is set to
0.0V.
•
In the case of automatic calculation, calculated value will be displayed auto-
matically after printing.
Press the
FEED
button to save the setting and move to the next screen.
Displays the current voltage of Gap sensor on the upper part of the display.
Adjust the light emission level of Gap sensor with the
LINE
button. This offset
determines how soon the sensor will respond to an incoming Gap.
The adjustment range is between 00 to 03 and is shown on the bottom line of
the display. The initial setting is 02.
Press the
FEED
button to save the setting and move to the next screen.
Displays the current voltage of Gap sensor on the upper part of the display.
Adjust the light reception level of Gap sensor with the
LINE
button. This offset
determines how soon the sensor will respond to an incoming Gap.
The adjustment range is between 00 to 15 and is shown on the bottom line of
the display. The initial setting is 07.
Press the
FEED
button to save the setting and move to the next screen.
TEST PRINT
FEED->PRINT
TEST PRINT
PRESS FEED KEY
SENSOR ADJ(MAN)
I-MARK(E)
02
ADJUST LEVEL
X.XV
SENSOR ADJ(MAN)
I-MARK(R)
07
ADJUST LEVEL
X.XV
SENSOR ADJ(MAN)
I-MARK(R)
1.4
SLICE LEVEL
X.XV
V
SENSOR ADJ(MAN)
GAP(E)
02
ADJUST LEVEL
X.XV
SENSOR ADJ(MAN)
GAP(R)
07
ADJUST LEVEL
X.XV
Preliminary