Section 7: Interface Specifications
Page 7-4
CW408 Operator Manual
7.3 LOCAL AREA NETWORK (LAN) ETHERNET (Cont’d)
7.3.1 Basic Specifications (Cont’d)
Communication
Configuration
The following communication settings are available in the Interface mode of the
printer.
Item
Setting Range
Protocol
STATUS3
STATUS4 (Cyclic response mode)
STATUS4 (ENQ response mode) (Default)
IP address
0.0.0.0 ~ 255.255.255.255
Default: 192.168.1.1
Subnet mask
0.0.0.0 ~ 255.255.255.255
Default:255.255.255.0
Gateway address
0.0.0.0 ~ 255.255.255.255
Default:0.0.0.0
IP address setting
DHCP Disable (Set by manual)
DHCP Enable
Default: Disable (Set by manual)
RARP setting
RARP Disable
RARP Enable
Default: Disable
* IP address, Subnet mask, Gateway address can be set by printer setting tool,
such as SATO All-In-One application.
* If the printer cannot obtain IP address from DHCP server at DHCP enabled,
default of IP address becomes [0.0.0.0].
Maximum Receive
Buffer Capacity
2.95 MB
Buffer near full
Buffer near full
0 MB
2.95 MB
Remaining 0.95 MB
Remaining 1.95 MB
occurred
released
Preliminary