Section 8: Appendix
CW408 Operator Manual
Page 8-7
8.4 BASE REFERENCE POINT ADJUSTMENT (Cont’d)
8.4.3 Limitation on Base Reference Point Adjustment
After adjustment of the print position and the stop position for options, the distance between these two
positions should not exceed one pitch size (including liner) of the media.
Refer to the figure and table below for the adjustment range of the distance between the print position and the
stop position for options.
Adjustment range of the distance between the print position and the stop position for options:
Types of Options
Adjusted Distance
(Min.)
Initial Distance
Adjusted Distance
(Max.)
Tear-off
12.5 mm (0.49”)
20.0 mm (0.78”)
27.5 mm (1.08”)
Cutter
16.5 mm (0.65”)
24.0 mm (0.94”)
31.5 mm (1.24”)
Dispenser
5.5 mm (0.22”)
13.0 mm (0.51”)
20.5 mm (0.81”)
Print position
(Initial)
Stop position
for options
(Initial)
+3.75 mm
(+0.15”)
Initial distance
-3.75 mm
(-0.15”)
+3.75 mm
(+0.15”)
-3.75 mm
(-0.15”)
Adjusted distance (Max.)
The range of the adjusted distance includes
the base reference point of two media.
Adjusted distance
(Min.)
Preliminary