90
F7 Group
:
Process Closloop PID Parameters
(
Toal 34
)
Code
Name
Setting Scope
Min
Unit
Default
ed
Value
Address
Cha
nge
F7.17~
F7.28
Reserved
-
- -
711H~
71CH
*
F7.29
PID Feedback
break line
detection
0.0
~
80.0%
0.1%
0.0%
71DH
×
F7.30
PID Feedback
break line
detection time
0
~
999.9s
1s 0.0s 71EH
×
F7.31~
F7.33
Reserved -
- -
71FH
~721H
*
F8 GROUP
:
Multi Parameters
(
total 21
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address
Chan
ge
F8.00
MS freq 1
Low limit
frequency
~
Upper limit
ferquency
0.01Hz
5.00Hz 800H
○
F8.01
MS freq 2
10.00Hz
801H
F8.02
MS freq 3
20.00Hz
802H
F8.03
MS freq 4
30.00Hz
803H
F8.04
MS freq 5
40.00Hz
804H
F8.05
MS freq 6
45.00Hz
805H
F8.06
MS freq 7
50.00Hz
806H
F8.07
MS freq 8
Low limit
frequency
~
Upper limit
ferquency
0.01Hz 50.00Hz
807H
○
F8.08
MS freq 9
808H
F8.09
MS freq 10
809H
F8.10 MS
freq
11
80AH
F8.11
MS freq 12
80BH
F8.12
MS freq 13
80CH
F8.13
MS freq 14
80DH