97
FD Group
:
Professional function parameters 2
(
total 31
)
Code
Name
Setting Scope
Min
Unit
Default
ed
Value
Address
Cha
nge
FD.00
Simple PLC
mode
LED Units
:
PLC run mode
0
:
no-action
1
:
Stop after ending single
running
2
:
keep the final value when
single running ends
3
:
Continuous circulation
LED Tens
:
Start mode
0
:
Run from the first stage
1
:
Continue to run from stage
frequency of the break time
2
:
Continue to run from run
frequency of the break time
LED Hundreds
:
Power failure
storage
0
:
No memery
1
:
Memery
LED Thousands
:
Select the
unit of stage time
0
:
Second
1
:
Minute
1
0000 D00H ×
FD.01
Stage 1
setting
LEDUnits
:
0
:
Select mulit frequency 1
(F8.00)
1
:
Frequnecy depends on
thefunction code of F0.02
LED Tens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run command
1
00 D01H
○
FD.02
Stage 1 run
time
0.0~6500 s(min)
0.1
20.0s
D02H
○