33
6.5
Current vector control parameter
(
F4
)
6.6
Multi-function terminal
(
F5
)
The multi-function terminals can realize various functions. You may
assign functions to them by setting parameters F5.00~F5.04. Please
refer to Table 6-3. Take X1~X3 for example in the following
description.
Setting
Functions
Setting
Functions
0
No function
1
Foreward run
2
Reverse run
3
MS frequency 1
4
MS frequency 2
5
MS frequency 3
6
External fault normally-open
input
7
External fault normally-closed
input
8
Reset signal
9
Forward jog
10
Reverse jog
11
Coast-to-stop input
12
Frequency increase(UP)
13
Frequency decrease(DN)
F4.00~F4.10 Reserved
Reserved
F5.00 Function of multi-function terminal X1
Range
:
0
~
43
【
1
】
F5.01 Function of multi-function terminal X2
Range
:
0
~
43
【
2
】
F5.02 Function of multi-function terminal X3
Range
:
0
~
43
【
0
】
F5.03 Function of multi-function terminal X4
Range
:
0
~
43
【
0
】
F5.04 Function of multi-function terminal X5
Range
:
0
~
45
【
0
】
F5.05~F5.07 Reserved
Reserved