Inverter control word bits are defined as follows
:
Control word
(
bit
)
Value
Function
Description
Bit2
、
1
、
0
111B
Run Command
Start the inverter
110B Mode
0
stop
Stop according to setting
deceleration time
101B
Mode 1 stop
Free stop
011B Mode
2
stop
Reserved
100B
External fault stop
Freestop,Inverter display
external fault
Rest
No command
Bit3
1 Reverse
Run setup effective
operation direction (Inching
mode is invalid)
0 Forward
Bit4
1
Inching to run
froward
0
Inching to stop the
forward run
Bit5
1
Inching to reverse
0
Inching to stop
reverse
Bit6
1
Allow acceleration/
deceleration
Reserved
0
Forbidden for
acceleration/
deceleration
Bit7
1
Host computer
control valid
The control word sent by the
current FC is effective
0
Host computer
control invalid
The control word sent by the
current FC is invalid
Bit8
1
The main set
effective
Enable the main setting
0
The main set is
invalid
Ban the main setting