111
Control word
(
bit
)
Value
Function
Description
Bit9
1
Failure reset
effective
0
Failure reset is
invalid
Bit15~Bit10
000000
B
Reserved
Note
:
Inching to run given (Bit4, Bit5) shall not be effective
simultaneously with the control word Bit0 ~ Bit2
!
The inverter status word 1 bits are defined as follows
:
Status word
(
bit
)
Value
Function
Remark
Bit0
1
Inverter
operation
0
Inverter stop
Bit1
1
Inverter reverse
0
Inverter forward
Bit2
1
Reach main
setting
0
Not reach main
setting
Bit3
1
Allow
commmunciation
control
0
Ban
commmunciation
control
Bit7~4 0000B
Reserved
Bit15~8 00~0xFF
Faule
code
0
:
Normal
;
None 0
:
Fault
,
Specific fault
codes details refer to the
inverter user manual
E.g. ,motor overload F.oL2
will be the fault code of
0x0E
,
undervoltage will be
0x1F
。