INTEGRA/-S/-G/-GS User Manual WEB GUI
SAF Tehnika JSC
89
Modify mode
1)
Indicates low, high, and delta values of the parameters (status mode);
“Low value”,
“High value” and “Delta value” fields for all parameters become editable w
hen
“Default value” is deselected
(modify mode);
2)
Set all to default
–
resets “Low value”, “High value” and “Delta value” for all
parameters to factory defaults;
3)
Default value
–
deselect to activate manual threshold modification;
4)
By pressing
„Execute configuration”
,
changes made to the corresponding section
apply only to the local side Integra/Integra-S/Integra-G/Integra-GS.
CLI commands (
Chapter 4: COMMAND LINE INTERFACE
log sensor info
Use to show the configuration of sensor thresholds.
log sensor mgmt
<sensor>
control {enable|disable}
Use to enable or disable a sensor.
log sensor mgmt
<sensor>
thold
<min> <max> <delta>
Use to set sensor’s min, max thresholds
, and delta values
manually.
log sensor mgmt
<sensor>
time
<0…30>
Use to set sensor hysteresis time in seconds. Will be used to
show a value in orange color indicating that the sensor value
recently exceeded its thresholds.
log default
{all| group|
sensors [sensor]}
Use to set group, individual sensor, or all sensor configuration
to default.
log sensor list
Use to list all available sensors.
Содержание Integra
Страница 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...
Страница 46: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 46 Modify mode Slave status after enabling aggregation...
Страница 47: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 47 Master status after enabling aggregation Press button...
Страница 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...
Страница 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...
Страница 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...