INTEGRA/-S/-G/-GS User Manual WEB GUI
SAF Tehnika JSC
44
b
1.
Mandatory
fiber optic cable between LAN2
(optical) ports on both units.
2.
Cable for powering Slave FODU. You can use a 2-
wire power cable with DC power adapter (P/N
D0ACPW01) or a standard Ethernet cable with the
PoE injector. Depending on power consumption
cable length can be extended up to 700m. Refer to
chapter
for details.
3.
Electrical Ethernet cable (1000Base-T) between
PoE injector’s (#2) DATA+PWR port and LAN1
(electrical) port of the Master FODU. Both data
and power are carried, therefore the total length of
cables #3 and #5 combined should not exceed
100m.
4
.
Fiber optic cable between LAN3 (optical) ports on
both units. Provides management access to the
Slave FODU.
5.
Electrical Ethernet cable (1000Base-T) between
PoE injector’s (#1 or #2) DATA port and CPE or
both traffic and management traffic. The total
length of cables #3 and #5 combined should not
exceed 100m.
Advantages:
1) external switch not required; 2) optical cable used only for interconnection between
both FODUs; 3) only two cables are installed between FODUs and an indoor facility.
c
1.
Mandatory
fiber optic cable between LAN2 (optical)
ports on both units.
2.
Cable for powering the Slave FODU. You can use a
2-wire power cable with a DC power adapter (P/N
D0ACPW01) or a standard Ethernet cable with the
PoE injector. Depending on power consumption
cable length can be extended up to 700m. Refer to
chapter
3.
Cable for powering the Master FODU. You can use
a 2-wire power cable with a DC power adapter (P/N
D0ACPW01) or a standard Ethernet cable with the
PoE injector. Depending on power consumption
cable length can be extended up to 700m. Refer to
chapter
for details.
4.
Fiber optic cable between LAN3 (optical) port of
the Slave FODU and external switch. Provides
management access to the Slave FODU. If the
Master link is down, traffic will be redirected
through this cable.
5.
Electrical Ethernet cable (1000Base-T) between the
external switch and CPE for both traffic and
management traffic.
6.
Fiber optic cable between LAN3 (optical) port of
the Master FODU and an external switch for both
traffic and management traffic.
Advantages:
1) solution provides the greatest cable length for powering
Integra/Integra-S/Integra-
G/Integra-GS
and the length of optical cable for traffic/management can be up to 10km. For details on
the length of the power cable refer to chapter
; 2) Slave link will be able to reconfigure to 1+0
in case the Master unit goes down (2+0 redundancy).
Содержание Integra
Страница 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...
Страница 46: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 46 Modify mode Slave status after enabling aggregation...
Страница 47: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 47 Master status after enabling aggregation Press button...
Страница 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...
Страница 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...
Страница 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...