
INTEGRA/-S/-G/-GS User Manual WEB GUI
SAF Tehnika JSC
34
Modifying basic system parameters
To proceed with the initial configuration, press the MODIFY button and the entry fields will
appear for adjustable values:
1
Tx power
The available range depends on the radio model and selected modulation. The actual range
will be indicated in the brackets. If a Variable Tx power bandwidth profile was selected, the
available range is the maximum Tx power at 4QAM modulation when ACM downshift occurs.
2
Tx frequency
The available range depends on the frequency band, subband, radio side, and channel
bandwidth selected. The actual range will be indicated in the brackets.
Tx frequency range indicates the range of central frequencies for the configured channel
bandwidth.
Содержание Integra
Страница 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...
Страница 46: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 46 Modify mode Slave status after enabling aggregation...
Страница 47: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 47 Master status after enabling aggregation Press button...
Страница 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...
Страница 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...
Страница 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...