SAF Integra Скачать руководство пользователя страница 41

INTEGRA/-S/-G/-GS User Manual                                                      WEB GUI 

 

 

SAF Tehnika JSC                                                                                                                                                 

 

         41 

 

ACM  (Adaptive  Coding  and  Modulation)

 

for  further  details)  enables  adaptive 

modulation  change  according  to  MSE  value.  Modulation  indicates  maximum 
modulation, while the minimum is 4QAM. 
In  case  the  current  Tx  power  value  is  above  the  maximum  value  for  any  of  the 
modulations, the maximum value will be indicated. 

14)

 

By  pressing 

„Execute  configuration”

,

  changes  made  to  the  corresponding  section 

apply only to the local side 

Integra/Integra-S/Integra-G/Integra-GS

. If 

„Rollback on”

 is 

selected, the configuration will be reverted in case erroneous configuration changes 
are applied.

 

Pressing 

„Execute for both” 

applies changes made to the corresponding section both 

for local and remote side 

Integra/Integra-S/Integra-G/Integra-GS

 FODUs. 

CLI commands (

Chapter 4: COMMAND LINE INTERFACE

) 

radio 

[status]

 

Use to show radio status. 

radio power

 <Tx power> 

Use to set Tx power in dBm. 

radio frequency

 <frequency> 

Use to set Tx frequency in kHz. 

radio rssi-led

 {disable | enable 

[mode {1|2|3}]} 

Use to enable or disable RSSI LED operation. 

radio rssi-led

 

enable mode

 

{1|2|3} 

polarization

 <seconds>

 

Use to enable the red RSSI LED's operation for n seconds. 
Its main purpose is an indication of polarization alignment 
accuracy  +/-  3deg.  Functionality  may  not  be  available  in 
older HW revisions. 

radio tx-mute

 {<time>|disable} 

Use to mute the transmitter to a specific time in seconds 
or unmute. 

radio factory 

Use to reset radio settings to factory defaults 

 Tx power 

will be disabled and frequencies set to factory defaults. 

radio upgrade 

<firmware>

 

Use  to  upgrade  the  radio  firmware  version.  The  firmware 
file must be located in the FTP directory. 

radio version 

Use to check the radio software version 

radio atpc [status] 

Use  to  check  the  status  of  ATPC  (Automatic  Transmit 
Power Control). 

radio atpc state 

{enable|disable} 

Use to enable/disable ATPC. 

radio atpc delay

 <1..5> 

Use to define the ATPC update period. 

radio atpc rx_level 

<-75..-43>  <-

72..-40> 

Use  to  define  ATPC  remote  Rx  level  min  and  max 
thresholds. 

modem configuration set 

<bandwidth> <min_mod> 
<max_mod> 

Use to set modem configuration 

 bandwidth, minimum 

and maximum modulation.  

“e” suffix indicates “AES”

Содержание Integra

Страница 1: ...SAF Tehnika JSC 1 User manual Integra Integra S Integra G Integra GS VER 2 37 FW 3 20 19...

Страница 2: ...rt 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequen...

Страница 3: ...etup in the indoor environment 26 Chapter 3 WEB GUI 27 Initial configuration 27 Powering Integra Integra S Integra G Integra GS FODU and connecting to PC 27 PoE injector P N I0ATPI22 27 Universal prog...

Страница 4: ...iguration IP configuration 109 System Configuration SNMP configuration 110 System Configuration Configuration file 114 System Configuration Users configuration 117 System Configuration System configur...

Страница 5: ...DIUS authentication 155 Configuration of the RADIUS server authentication 155 Assigning administrator rights to a RADIUS user 156 Chapter 7 TOOLS 157 Link Layer Discovery tool 157 MIB files 162 Chapte...

Страница 6: ...esignates 1ft antenna diameter and ETSI Class 3 0 1ft 20cm antenna diameter and ETSI Class 3 2 2ft antenna diameter and ETSI Class 3 3 3ft antenna diameter and ETSI Class 3 4 4ft antenna diameter and...

Страница 7: ...ference levels Frequency range Exposure characteristics Equivalent plane wave power density Seq W m2 Average time period min 5 8 GHz occupational 458 cm 181 in 50 68 f1 05 f in GHz general public 1025...

Страница 8: ...s specify or refer to exposure limits comparable to those given above e g 1999 519 EC Council Recommendation of July 12 1999 on the limitation of exposure of the general public to electromagnetic fiel...

Страница 9: ...ALK002 RJ 45 connector 8P shield solid FOACNR02 Installation manual D0DBSRM1 Integra Integra G FODU assembling mounting bracket and installing with an antenna on a pole Disassembled mounting bracket a...

Страница 10: ...nut 12 Fixation plate 13 Side screw flange nuts 14 Grounding flange nut The numbers of the mounting bracket and Integra Integra G FODU parts in the next sections will be mentioned in square brackets C...

Страница 11: ...ed nuts and fixation plate 10 11 12 13 14 3 Removed parts must be attached back with a 90 degree offset see above The gap between side screw flange nuts 13 and fastening angles should be 5mm 4 View of...

Страница 12: ...be screwed on exposing approx 20mm 0 8 in of threaded rods 4 Insert both threaded bolts into two available holes of the mounting clamp Put hex nuts 7 on the other side of the clamp and screw on the th...

Страница 13: ...hat both horizontal and vertical alignment eye screws are turned to the mast before attaching Integra Integra G FODU 10 Attach Integra Integra G FODU with the antenna to the mounting bracket so that s...

Страница 14: ...h mounting bracket clamps for housing and pipe 3 For initial alignment make sure that elevation is approximately at zero degrees angle by adjusting hex flange nuts 9 on the vertical alignment eye scre...

Страница 15: ...azimuth and elevation eye screws right side screw on Integra FODU and hex flange bolt on azimuth angle indicator with torsion 20 25 N m 8 Additionally tighten the following screws marked with red dot...

Страница 16: ...ed 1 Using a size 5 allen wrench loosen one clamp completely and the second clamp by a half turn 2 Put Integra S Integra GS on the antenna adapter flange by hooking a half turn loosened clamp at the t...

Страница 17: ...Integra GS Adjust polarization so that the interface ports are located at the lower side of the Integra S Integra GS 6 Verify polarization accuracy with a level by placing it on the top edge of the I...

Страница 18: ...ting signal polarization is determined by Interface on antenna OMT To change signal polarization please rotate only the antenna interface as the radio always remains in the vertical position 11 GHz In...

Страница 19: ...osition Example of vertical polarization interconnection 2 Example of horizontal polarization interconnection 3 Put Integra S Integra GS on the antenna adapter flange by hooking a half turn loosened c...

Страница 20: ...tegra S Integra GS FODU is properly leveled Tighten all four fixation clamps properly 6 Final view of assembled Integra S Integra GS 6 13GHz 1 0 setup Integra S Integra GS 6U 6L 7 8 10 11 13 are separ...

Страница 21: ...2 Attach Integra S Integra GS 6 13GHz FODU to the OMT using both upper clamps Integra S Integra GS 6 13GHz FODU features twisted polarization flange and resulting signal polarization is determined by...

Страница 22: ...OMT and antenna 6 Final view of assembled Integra S Integra GS 6 13GHz 2 0 setup Integra S Integra GS 6U 6L 7 8 10 11 13 are separate FODU models For connecting Integra S GS 15 42GHz to an OMT please...

Страница 23: ...e used and install an SFP module 3 Disassemble the conduit kit and put its parts in the following sequence left FODU direction right CPE direction 4 Push the FO cable from the LC connector side throug...

Страница 24: ...w on the remaining four hex flange nuts 4 on all threaded rods 2 Attach waveguide transition flange to the mounting bracket using size 5 Allen wrench Put the flat side of the transition flange 5 on th...

Страница 25: ...the remaining four hex flange nuts 4 on all threaded rods 2 Attach the waveguide transition flange to the mounting bracket using a size 5 Allen wrench Put the flat side of the transition flange 5 on...

Страница 26: ...a test kit available for purchase as an optional accessory P N is DxxTST01 where xx frequency band e g D11TST01 for 11GHz The exception is 17 and 24GHz radios The test kit consists of an adapter flan...

Страница 27: ...t cable Cat5e or better When powered the RSSI LED will light up a solid green color for approx 20sec Afterward RSSI LED will go out for approx 35sec and eventually start blinking indicating the curren...

Страница 28: ...tor SHORT Auto PoE mode if S4 is UP see table below Manual PoE mode if S4 is UP see table below The back panel has 4 switches to operate the PoE injector in different modes The appropriate Imax select...

Страница 29: ...net Connectors Shielded RJ45 jacks Data Lines Pins 1 2 3 6 4 5 and 7 8 Power Lines 1 2 and 4 5 3 6 and 7 8 Power Clamping Voltage 70 V Max data cable length 100 m Color indication can be disregarded i...

Страница 30: ...e ready to connect to the Web GUI or establish a SSH Telnet connection Refer to Chapter 4 COMMAND LINE INTERFACE for the details on how to connect to other CLI interfaces serial SSH Telnet Accessing W...

Страница 31: ...d if you want the browser to remember entered login credentials 6 Press Log in button Switch to secure connection HTTPS indicates that HTTP protocol is being used Press on the link and you will be red...

Страница 32: ...Integra G Integra GS FODU you are connected to including Model name System name IP address Serial number Uptime Firmware version User name 2 Menu panel Allows navigating between the Main page Main and...

Страница 33: ...ary Shows one to four default value three selected parameters of the local and remote systems as well as Tx polarization as read from the internal accelerometer Values appear in red color in case of e...

Страница 34: ...cted modulation The actual range will be indicated in the brackets If a Variable Tx power bandwidth profile was selected the available range is the maximum Tx power at 4QAM modulation when ACM downshi...

Страница 35: ...ode longer FEC overhead while Weak FEC indicates a higher capacity mode shorter FEC overhead Weak FEC is available only for the highest modulation for the selected channel bandwidth ACM stands for Ada...

Страница 36: ...ATPC is enabled or disabled 6 Duplex shift shows the margin between the transmitting and receiving frequencies 7 Tx frequency shows the transmitting frequency 8 Rx frequency shows the receiving frequ...

Страница 37: ...indicates the acquired status of the modem During normal operation Locked will be shown 14 MSE shows Mean squared error value lower value means better signal quality 15 FEC load shows the load of Forw...

Страница 38: ...figuration The Radio configuration page is available in the menu Over The Air Radio Configuration Refer to the chapter Radio configuration extra fields for a description of the extra fields of the 17...

Страница 39: ...the configured channel bandwidth The default frequency range indicated on the label is defined for 3 5MHz channel bandwidth 3 Tx mute 10 sec Indicates whether Tx mute is enabled or disabled status mod...

Страница 40: ...Values should be defined between 75 and 40 dBm Please refer to the ATPC Automatic Transmit Power Control description for further details The Minimum Rx level threshold should be set at least 10dB abo...

Страница 41: ...radio rssi led disable enable mode 1 2 3 Use to enable or disable RSSI LED operation radio rssi led enable mode 1 2 3 polarization seconds Use to enable the red RSSI LED s operation for n seconds Its...

Страница 42: ...r HW protection will be available only when an external switch is used Please see below interconnection schemes c and d Header compression cannot be used with 2 0 aggregation configured Two pairs of I...

Страница 43: ...xternal switch or directly on LAN1 or LAN3 ports in addition to LAN2 interconnection for aggregation protection to work This connection is used to interchange 2 0 1 1 aggregation protection statuses f...

Страница 44: ...ts on both units 2 Cable for powering the Slave FODU You can use a 2 wire power cable with a DC power adapter P N D0ACPW01 or a standard Ethernet cable with the PoE injector Depending on power consump...

Страница 45: ...erefore the total length of cables 3 and 4 combined should not exceed 100m 4 Electrical Ethernet cable 1000Base T between PoE injector s 2 DATA port and external switch The total length of cables 3 an...

Страница 46: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 46 Modify mode Slave status after enabling aggregation...

Страница 47: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 47 Master status after enabling aggregation Press button...

Страница 48: ...ows specifying aggregation role modify mode 3 Current role Indicates the current role It may differ from the configured role in case Master protection is enabled the alternate device is or was not ava...

Страница 49: ...units is shown Local the unit you are currently connected to alternative unit interconnected with the local unit remote unit on the remote side of the link synchronized to the local unit remote alter...

Страница 50: ...dicates the number of packets transmitted by Master FODU 27 Combiner packets Indicates the number of packets received by Master FODU 28 FCS errors on air Indicates the number of FCS errors received by...

Страница 51: ...none master slave Use to force traffic to transmit solely via Master or Slave FODU Aggr mprot enable id LAN1 LAN3 Use to enable master protection by specifying instance ID and traffic port LAN1 or LA...

Страница 52: ...improved interactive response time are additional important benefits gained by header compression In summary header compression is the process of compressing excess protocol headers before transmitti...

Страница 53: ...ssion gain Gross Indicates compression percentage between ingress and egress data including GFP Generic Framing Procedure overhead 7 By pressing Execute configuration changes made to the corresponding...

Страница 54: ...Execute configuration changes made to the corresponding section apply only to the local side Integra Integra S Integra G Integra GS If Rollback on is selected the configuration will be reverted in ca...

Страница 55: ...t the uploaded bin firmware file from the list and press Upgrade firmware The remote side should be upgraded first f Repeat steps a e for the local side of the link 2 Upload and activate license key e...

Страница 56: ...oaded lic license file from the list and press Activate e Repeat a e for the local side of the link 3 Set bandwidth with AES a Go to Main page b Press button c Select the required bandwidth with AES a...

Страница 57: ...working Networking Ethernet VLAN The VLAN configuration window provides the configuration of port based Ethernet Virtual Local Area Networks VLANs allowing up to 4094 different VLAN IDs It is possible...

Страница 58: ...will be removed from tagged egress packets on particular ports as well but the VLAN ID will be removed according to the tagged untagged configuration see below of that particular port 3 Name Indicate...

Страница 59: ...to VLAN configuration for QinQ network vlan set mode qinq tpid 0x0001 0xFFFF Use to set tag protocol identifier TPID for S TAG network vlan set vid 1 4094 add tagged untagged LAN1 LAN2 LAN3 Use to add...

Страница 60: ...allows setting rate CBS on a particular VLAN rate item in kB modify mode 4 Add Delete Press Add to add entered VLAN rate or press the red cross to delete this entry 5 By pressing Execute configuration...

Страница 61: ...t switch ports In case a license with an Ethernet rate limitation is applied the Ethernet limitation will be indicated as the egress rate of the WAN port Status mode Press button Modify mode 1 Egress...

Страница 62: ...By pressing Execute configuration changes made to the corresponding section apply only to the local side Integra Integra S Integra G Integra GS If Rollback on is selected the configuration will be rev...

Страница 63: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 63 Status mode Press button...

Страница 64: ...table show Use to show MAC table entries network mac table info Use to show MAC table statistics network mac table clear vlan vid Use to clear MAC table entries for a specific VLAN ID network mac tabl...

Страница 65: ...removing temporarily entered static MAC address Remove or deleting permanently entered static MAC address Add 5 By pressing Execute configuration changes made to the corresponding section apply only t...

Страница 66: ...TEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 66 Networking Ethernet Spanning Tree The Spanning Tree page provides the configuration of Rapid Spanning Tree Protocol Rapid STP Status mode Press butt...

Страница 67: ...s stored for a separate port status mode allows specifying the value of Max Age in seconds modify mode 4 Forward Delay 4 30 sec Indicates configured time period that determines the time a separate por...

Страница 68: ...Bad MSTP BPDUs Indicates how many bad MSTP BPDUs packets were received 18 Bad RSTP BPDUs Indicates how many bad RSTP BPDUs packets were received 19 Bad Conf BPDUs Indicates how many bad STP BPDUs pack...

Страница 69: ...tion or 1 1 protection is enabled 3 Link status Indicates whether a link with the appropriate port is established as well as its link speed 4 Link speed Indicates whether link speed is configured to a...

Страница 70: ...ork port set port admin state enable disable Use to enable or disable a particular port network port set LAN1 speed auto 100fdx 100hdx 10fdx 10hdx Use to change speed and duplex setting on LAN1 port T...

Страница 71: ...es Locked if SyncE is operating normally 4 Source port configuration Allows specifying SyncE source port 5 Disable Enable Allows enabling or disabling SyncE operation Configuration examples 1 Integra...

Страница 72: ...n properly on LAN2 and LAN3 ports only with appropriate SFP modules CLI commands Chapter 4 COMMAND LINE INTERFACE network sync enable LAN1 LAN2 WAN Use to enable SyncE on a port connected to a clock s...

Страница 73: ...0BASE T 100M Port current port used as a clock source State clock status Locked if SyncE operates normally State info additional information Networking QoS General QoS configuration The General QoS co...

Страница 74: ...mapping 5 Schedulers mode Indicates whether frame based SP RR WRR Strict Priority Round Robin Weighted Round Robin or byte based scheduling schemes SP DWRR Strict Priority Deficit Weighted Round Robin...

Страница 75: ...e Use to select the scheduler s mode frame SP RR WRR or byte SP DWRR network qos show config LAN1 LAN2 LAN3 WAN all Use to show QoS user configuration network qos show info LAN1 LAN2 LAN3 WAN all Use...

Страница 76: ...e packets will according to 802 1p priority be put in if 802 1p QoS prioritization is enabled on LAN3 port status mode allows modifying default mapping of priority values and queues modify mode 5 WAN...

Страница 77: ...S G GS User Manual WEB GUI SAF Tehnika JSC 77 Networking QoS DiffServ mapping The DiffServ mapping page allows customizing the mapping of DSCP priority tags and available QoS queues Status mode Press...

Страница 78: ...side Integra Integra S Integra G Integra GS If Rollback on is selected the configuration will be reverted in case erroneous configuration changes are applied CLI commands Chapter 4 COMMAND LINE INTERF...

Страница 79: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 79 Status mode Press button Modify mode 1 LAN1 LAN2 LAN3 WAN Tabs allow selecting a particular port...

Страница 80: ...statistically over time bandwidth used by each queue will be closer to the configured value Default ratio is equal for all queues 1 1 1 1 1 1 1 1 4 Droplimit Indicates droplimit buffer size assigned...

Страница 81: ...e for a particular port network qos set WAN cosq lowlatency enable disable queue 0 7 Use to enable or disable low latency queue thus disabling or enabling packet fragmentation This functionality is av...

Страница 82: ...uration changes made to the corresponding section apply only to the local side Integra Integra S Integra G Integra GS If Rollback on is selected the configuration will be reverted in case erroneous co...

Страница 83: ...t 5000 alarm entries in total The full alarm log can be downloaded by pressing on Alarm event log file The last page of log entries is shown by default Alarm entries are mostly distributed in two grou...

Страница 84: ...e specific page number to navigate to the required page 7 Filter press to filter alarms from a certain source node e g Radio 8 Alarm event log file press the link to download the full alarm log text f...

Страница 85: ...g entry repetitions to be monitored log event configure status Use to display the current configuration of grouped repetitive alarm event log entries filter Performance Alarm Sensor configuration The...

Страница 86: ...g groups status mode allows dragging to any of the existing groups thus specifying how the sensor will be treated Unchecking the checkbox next to the sensor disables the sensor modify mode 3 Add group...

Страница 87: ...e delete Use to delete a group log group mgmt name remove destination event perf snmp syslog Use to remove a destination from a group log group mgmt name remove sensor sensor Use to remove a sensor fr...

Страница 88: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 88 Status mode Press button...

Страница 89: ...only to the local side Integra Integra S Integra G Integra GS CLI commands Chapter 4 COMMAND LINE INTERFACE log sensor info Use to show the configuration of sensor thresholds log sensor mgmt sensor co...

Страница 90: ...rameters over a chosen time period as curves Available parameters will depend on the Sensor Configuration Any two parameters can be shown at a time By default Rx level dBm and MSE dB are selected Not...

Страница 91: ...15 or 60 minutes 4 Indicates start and end date time of period displayed and allows selecting a specific period to show 5 Period length Indicates the length of the currently displayed period 6 Renew P...

Страница 92: ...tes 4 Indicates start and end date time of period displayed and allows selecting a specific period to show 5 Period length Indicates the length of the currently displayed period 6 Log entries per page...

Страница 93: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 93 log perf clear Use to clear performance log Performance Ethernet Ethernet switch statistics...

Страница 94: ...INTEGRA S G GS User Manual WEB GUI SAF Tehnika JSC 94 Status mode...

Отзывы: