Cautionary warning to be followed to
guarantee the safety of the operator and
those persons present in the work area.
Failure to comply with instructions
may result in electric shock.
Failure to comply with instructions
may result in damage to the motor
pump or to the system.
1. GENERAL INFORMATION
Before performing any operation on the machine, it is indispensable that you be completely familiar with the entire use and maintenance manual. The manufacturer
declines all responsibility for improper use of the product, for damage caused following operations not contemplated in this manual or unreasonable interventions.
Instructions and limitations contained in this manual are in reference to standard models. For all other versions and all other situation non contemplated in the manual
you should contact the technical service.
Each transport, installation, connection, setting at work, control and eventual maintenance or stop operation shall be executed by trained and qualified
staff. Furthermore, possible local regulations or directions not mentioned in this manual must be taken into consideration as well. For trained and qualified
staff make reference to the definition stated in the IEC 60364.
Tampering with the product is prohibited.
The user is responsible for dangers or accidents in relation to other persons and their property.
Use the pump / electric pump only for the purposes described in Paragraph 4. Any other use can be a cause of accidents.
Before executing any operation, the feeder cables shall be disconnected.
Never touch the electric pump while it is working.
2. SAFETY INFORMATION
3. TRANSPORT, HANDLING AND INTERMEDIATE STORAGE
The pump / electric pump has to be lifted observing the following recommendations, according to its weight (indicated on its packing): up to 20 kg: manually by one
person; from 20 to 60 kg: manually by two persons; more than 60 kg: by means of a suitable lifting device. The sling must be made as shown in fig.2. Adjust the
length of the cables or belts so that the load is maintained horizontal.
Use suitable means for lifting and transporting the electric pump: it may be damaged if it is knocked or if it falls, even if there is no apparent external damage,
and it may also damage things or persons.
4. TECHNICAL SPECIFICATIONS AND USE
PRODUCT DESCRIPTION
- Series IR and IR4P centrifugal electropumps with a monobloc impeller, directly coupled to a closed-construction asynchronous motor with external ventilation.
Motor and impeller are removable without disconnecting the pump body from the system pipes.
- MG series: single-impeller, single-block centrifugal type with rigid coupling, coupled to a standard B3/B5 form asynchronous motor. MG1: bare shaft pump, MG2:
pump with motor.
The bodies of all pumps conform to the UNI-EN 733 standard.
The motor and impeller can be removed without disconnecting the pump from the system pipes.
The identification data and technical characteristics of the pump/electropump are shown on the plate attesting to its conformity to CE standards (fig.1).
PARTS / OPTIONAL VERSIONS
In the standard version, the pump is made of cast iron EN-GJL-250 (UNI EN 1561). Upon request, it can be supplied in other materials (bronze, stainless steel,
etc.).
TECNICAL SPECIFICATIONS FOR STANDARD VERSIONS
Temperatures: refer to Table 1
Max working pressare: refer to Table 2
Motor (for electric pumps): Asynchronous, single or three-phase
Degree of protection: IP55
Insulation class: F
Standard voltages:
• Frequency 50 Hz: 1~: 220-240V up to 4 kW; 3~: 220-240/380-415V up to 4 KW and 380-415V / 660-720V starting from 5,5 kW.
• Frequency 60 Hz: 1~: 220V up to 4 kW; 3~: 220/380 V or 255-278/440-480 V up to kW 4; 380/660 V or 440-480/760-830V starting from 5,5 kW.
Allowable voltage variation:
±
5% Un
Max starts / h: refer to Table 3
Noise level : refer to Table 4
Bearing lubrication: Permanent grease
Hydraulic seals: Mechanical seals
Motor protection against overloads: protections have to be provided by the customer (see paragraph 5).
USE
Pumping of clean liquids and without solid bodies , for civil , industrial and agricultural uses.
Never use the electric pump in explosive atmospheres or to pump inflammable or dangerous liquids.
Do not use motor in swimming areas.
Avoid dry operation of the pump.
Always use the pump with a delivery (flow and head) indicated in the working diagram.
5. INSTALLATION
Before executing any operation, turn off the power and prevent it from being reconnected.
PRELIMINARY VERIFICATIONS
Verify that the data shown on the plate, and in particular, power, frequency, voltage, absorbed current, are compatible with the characteristics of the electric
line or current generator available. In particular, the voltage of the line voltage can have a variance of
±
5% from the nominal voltage value on the plate.
Verify that the protection and insulation grade indicated on the plate are compatible with the environmental conditions.
Verify that the chemical/physical characteristics of the liquid to be moved correspond to those specified on the order.
Verify the environmental conditions: SAER pumps can be installed in enclosed or, at any rate, protected areas, with maximum ambient temperature of +40
°
C in a non-explosive atmosphere.
GB
WARNING
WARNING
WARNING
WARNING
Содержание IR Series