161
Chapter 9 Features Using MIDI
Chapter 9
Preventing Reception of MIDI
Messages for a Specific Part
This setting prevents reception of MIDI messages for a
specific part during playback of a GM score.
fig.10-022
fig.10-022
1.
2.
Hold down [SHIFT] and press [MIXER].
The “PART RX SW” screen appears.
3.
Press CURSOR [
] or [
] to move the cursor to the
part to be set not to receive MIDI messages.
Pressing CURSOR [
] when the cursor is at “PART 7”
switches the display to the settings screen for PARTS 8–
16 (except PART 10).
4.
Press [INC/+] or [DEC/-] or rotate the VALUE dial to set
this to “OFF.”
PART 1-16: OFF, ON
OFF:
MIDI messages are not received.
ON:
MIDI messages are received.
MIDI Messages for Precise
Expressiveness in Performances
Messages for Hi-Hat Control
The TD-8’s hi-hat controller also transmits the depth to
which the pedal is pressed, using control change messages.
By default (factory preset), control change 4 is used.
Reception/transmission to/from an external MIDI sequencer
will use this number.
If a MIDI device that you are using already uses control
change numbers 4, you can change these numbers.
fig.10-023
1.
Press [SETUP], then [F2 (MIDI)], then [F1 (GLOBAL)],
and then [F2 (PAGE 2).
[SETUP] lights, and the “MIDI GLOBAL” screen
appears.
2.
Press CURSOR [
] or [
] to move the cursor to
“PEDAL CC.”
3.
Press [INC/+] or [DEC/-] or rotate the VALUE dial to
choose the control change number.
PEDAL CC:
OFF, MOD ( 1), FOOT ( 4),
GEN1 (16), GEN2 (17)
OFF
:
Hi-hat data control will not be received or transmitted
via MIDI IN or MIDI OUT.
MOD (1), FOOT (4), GEN1 (16), GEN2 (17)
:
The specified control change will be used for hi-hat
control. This setting will be used both for reception at
MIDI IN and for transmission from MIDI OUT.