General Instrument Functions
R&S
®
AREG100A
118
User Manual 1178.7417.02 ─ 04
The "Disk & Memory" tab secures controlled access to the mass memory and pre-
vents information from leaving a secure environment.
The remote commands available to control security settings are described in
USB Storage
Activates the access to external USB storage media.
To apply the change: enter the security password and confirm with "Accept". Otherwise
the change has no effect.
See also
Chapter 6.7.4, "Using a USB Storage Device for File Transfer"
Note:
Remove all USB memory devices before disabling the USB storage. If any USB
memory device remains connected, disabling is blocked, and the instrument returns a
warning message.
Volatile Mode
Activates volatile mode, so that no user data can be written on the internal memory
permanently.
In volatile mode:
●
Data that the instrument normally stores on the internal memory is redirected to
volatile memory.
●
The user directory is mapped to the volatile memory. You access the temporary
data just as data stored in the
/var/user/
Chapter 6.3, "Protecting Data"
●
Data on the internal memory cannot be changed. It is protected against modifica-
tion or erasure.
●
You can only save data:
–
Temporarily in the volatile memory
–
On a connected external storage device, such as a memory stick
To activate volatile mode: enter the security password, confirm with "Accept" and
reboot the instrument. Otherwise the change has no effect.
Activated volatile mode is indicated by an icon.
Remote command:
:SYSTem:SECurity:VOLMode[:STATe]
Using the Security Settings