
Remote Control Commands
R&S
®
NRX
299
User Manual 1178.5566.02 ─ 08
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<Window>]:TRACe:MEASurement:TRANsition:NEGative:
OVERshoot[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the relative amount of negative overshoot. See
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:
OVERshoot?
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<Window>]:TRACe:MEASurement:TRANsition:POSitive:
DURation[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the rise time of the first detected pulse. See
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:
DURation?
Suffix:
<Window>
.
1 to 4
Measurement pane
Parameters:
<value>
*RST:
OFF
Manual operation:
See
DISPlay[:WINDow<Window>]:TRACe:MEASurement:TRANsition:POSitive:
OCCurrence[:STATe]
<value>
Effective for pulse analysis measurements.
Enables or disables the display of the time when the signal passes through the medial
reference power level with rising edge. See
MEASurement:TRANsition:POSitive:OCCurrence?
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH