Remote Control Commands
R&S
®
NRX
236
User Manual 1178.5566.02 ─ 08
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Parameters:
<value>
Range:
-120.0 to +150.0
*RST:
-60.0
Default unit: dBm
Manual operation:
See
See
"Forward Scale Lower Limit, Reflection Scale Lower Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:CCDF
<value>
Sets the upper limit for the CCDF bargraph display.
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
100.0
Default unit: pct
Manual operation:
See
"Forward Scale Upper Limit, Reflection Scale Upper Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:UPPer[:DATA]:RATio:
RCOefficient
<value>
Sets the upper limit for the reflection coefficient bargraph display.
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH