PRT32 v1.0 fv74.7 Rev. A EN 

 

7/3/2009 

_________________________________________________________________________________________  

 
 

 

Page 24 of 29   

10.

 

Appendix 

Connection Terminals 

Connection 

terminal 

Offline  mode 

Online mode  

(unit connected to host ACU) 

Simple Stand-alone 

mode 

Full Stand-alone 

mode 

+12V Supply 

input 

plus. 

GND 

Supply input minus. 

CLK 

Can be configured as 

an input or output. 

CLOCK 

communication line. 

DATA 0 line for Wiegand formats 

CLOCK for Magstripe and RACS 

formats. 

DTA 

Can be configured as 

an input or output. 

DATA 

communication line. 

DATA 1 line for Wiegand formats 

DATA for Magstripe and RACS 

formats. 

IN1 

Input line, can be configured to several 

available functions). 

In Wiegand and Magstripe formats, 

the IN1 line activated by shorting it 

with the supply minus. When IN1 is 

triggered it turns the LED OPEN   to 

on and also activate acoustic signal 

on the internal buzzer. 

TAMP 

Isolated, tamper switch contacts, when case is closed contacts are shorted. 

Technical Specification 

Input voltage 

10...15 VDC 

Current consumption 

Avg. 60 mA 

Anti-sabotage protection 

(Tamper) 

NC contact, 50mA/24V  

Reading distance 

Up to 12 cm for ISO cards (depends on cards). 

Proximity cards 

EM UNIQUE 125 kHz, ASK modulation, 64 bits (compatible with 

EM4100/4102). 

Communication distance  

Between ACU and PRT reader in ONLINE mode: max. 150 m. 

Between main PRT reader and second PRT reader: max. 150 m. 

Between main PRT reader and XM-2 extension module: max. 150 m. 

Environmental class 

(according to EN 50131-1) 

Class I, Indoor, temperature: +5°C- +40°C, relative humidity: 10 to 95% 

(non-condensing). 

Ingress protection 

IP 30 

Dimensions 

H105 X W105 X D31 mm 

Weight 

~140 g 

Approvals 

CE 

 

 

Содержание PRT32

Страница 1: ...PRT32 v1 0 RFID PIN Access Reader Firmware v74 7 Installation and Programming Guide...

Страница 2: ...rs 8 6 2 Managing the users 9 6 3 User identification 9 6 4 Armed and Disarmed Modes 10 6 5 Arming and disarming of a reader 10 6 5 1 Examples 11 6 6 Unlocking a door 11 6 7 Operation with XM 2 I O ex...

Страница 3: ...power up of the reader the LED SYSTEM is on it means that either contents of reader s memory is corrupted or MASTER INSTALLER users are not programmed into a unit In this case reader must be complete...

Страница 4: ...ble to operate with XM 2 I O module nor additional PRT reader 4 General 4 1 Designed function The PRT32 reader has been designed for use in access control installations to enable user identification v...

Страница 5: ...ns for transmission of PIN codes LED BUZZER control input Offline mode Stand alone mode System settings stored in nonvolatile memory Enrolment up to 120 users User identification by a card or PIN code...

Страница 6: ...e code PIN As a result transmission from a reader is not equal to a full code of presented card code or entered PIN In Wiegand format a dual color LED STATUS lights steady in red The LED SYSTEM along...

Страница 7: ...essed Each entry of PIN code must be followed by pressing the key which is treated as the end of a PIN code In RACS format when IN1 is triggered the PRT32 will stop reading cards and PINs till the mom...

Страница 8: ...CLK DTA and IN1 can be configured fro several available functions Note The CLK and DTA lines may operate either as an input or output Installer has to program each line for adequate function The funct...

Страница 9: ...OGGLE LIMITED are solely authorized to control the Armed Disarmed mode of the reader they may have card and or PIN 6 2 Managing the users A new user can be registered in the device following either a...

Страница 10: ...general the reader s Armed Disarmed states have no effect on door unlocking unless the Access disabled when reader armed option will be enabled With this option activated access to the supervised roo...

Страница 11: ...the LED STATUS will change color Note If the option Access disabled when reader armed is enabled and the reader is in Armed mode then in order to unlock a door first you will have to switch the reader...

Страница 12: ...isarmed to Armed mode in order to disable unlocking of a door 6 7 Operation with XM 2 I O extension module In Full stand alone mode the PRT32 requires connection to an external XM 2 I O extension modu...

Страница 13: ...f the reader operates with a Door Contact The alarm indication is carried out over the Alarm Output line and optionally accompanied by the internal buzzer see option Door alarm indication on internal...

Страница 14: ...Offline mode If the unit is dedicated for Offline mode the installer must perform four programming steps Setting the reader to required Offline mode either Full or Simple stand alone mode Programming...

Страница 15: ...RACS data formats the JP1 and JP2 jumpers are used to specify reader s address ID number Note 2 For both Simple and Full stand alone modes the JP1 jumper is used to enter the Memory Reset procedure JP...

Страница 16: ...der 7 4 Memory Reset programming MASTER and INSTALLER users The Memory Reset erases all cards and PINs including MASTER and INSTALLER users Also it causes the reader restores the factory shipped defau...

Страница 17: ...tion mode selected for the reader either Simple Stand alone Mode or Full Stand alone mode the configuration digits C5 and C6 may have different effects for Simple Stand alone mode they configure the r...

Страница 18: ...exist output indicates alarm with a highest priority 7 Door Bell output whenever the door bell event occurs this output goes on for approx 5 seconds C6 0 7 Function settings for the REL2 output on the...

Страница 19: ...d Option Access disabled when reader armed disabled Last step completes the programming and the reader automatically leaves Installer Programming mode and returns to the operating mode either Armed or...

Страница 20: ...first unoccupied memory location with entered PIN his ID number is unknown 4 PIN Add single TOGGLE LTD user with a PIN only The new TOGGLE LTD user is stored in a first unoccupied memory location wit...

Страница 21: ...user with entered ID The user with entered ID is deleted both his card and his PIN are removed a new user can be programmed to use this ID index 0 Delete all users Reader deletes all users cards and P...

Страница 22: ...ong signal Error unknown identifier access denied Two long signals Attempt to assign the same function for two different input lines Three short beeps Command successfully completed OK signal Two shor...

Страница 23: ...ALLER users can be skipped A new factory delivered unit is configured for RACS Online mode with address ID 0 Disconnect power supply before making any electrical connections For installations on a met...

Страница 24: ...IN1 line activated by shorting it with the supply minus When IN1 is triggered it turns the LED OPEN to on and also activate acoustic signal on the internal buzzer TAMP Isolated tamper switch contacts...

Страница 25: ...ule is delivered with plastic box XM 2 Brd The XM 2 PCB module without casing Product History Hardware Firmware Date Description PRT32 v1 0 71 00 18 04 05 The initial product version PRT32 v1 0 72 00...

Страница 26: ...A EN 7 3 2009 _________________________________________________________________________________________ Page 26 of 29 Table List of users Site name Reader location ID Number Card number PIN Type User...

Страница 27: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 27 of 29...

Страница 28: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 28 of 29...

Страница 29: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 29 of 29...

Отзывы: