background image

PRT32 v1.0 fv74.7 Rev. A EN 

 

7/3/2009 

_________________________________________________________________________________________  

 
 

 

Page 9 of 29   

first read card and then enter PIN). The Card and PIN option can be set separately 

for primary and secondary reader. 

 

The PR32 reader supports five types (classes) of users:  

 

INSTALLER 

 

MASTER 

 

NORMAL 

 

TOGGLE  

 

TOGGLE LTD  

User types (user classes) 

INSTALLER 

This user is authorized for entry to the Installer Programming mode only. Enter 

INSTALLER PIN or read INSTALLER Card and the reader will enter Installer 

Programming mode. 

MASTER 

This user is authorized for entry to the User Programming mode only. Enter 

MASTER PIN or read MASTER Card and the reader will enter User Programming 

mode. 

NORMAL 

NORMAL users are solely authorized to unlock the controlled door, they may have 

card and/or PIN. 

TOGGLE 

TOGGLE users are authorized to unlock the controlled door and to control the 

Armed/Disarmed mode of the reader, they may have card and/or PIN. 

TOGGLE LTD 

TOGGL LTD (TOGGLE LIMITED) are solely authorized to control the 

Armed/Disarmed mode of the reader, they may have card and/or PIN. 

 

6.2.

 

Managing the users 

 

A new user can be registered in the device following either a simple or full 

programming procedure.  

 

The simple programming  procedure consists of programming of a PIN code or 

card into the unit without specifying the ID number of a user to whom the 

programmed PIN/card will be assigned — so the system simply stores the code 

entered/card presented in first unoccupied ID number.  

 

The full programming procedure requires to specify the ID number for the new 

user being programmed which has to be followed by entering his PIN code 

and/or presenting his card. 

Note: When you program a user using full programming procedure, you will be able 

later to selectively delete him by entering his ID number. If you program card/PIN 

using a simple programming procedure then to remove a given card/PIN from a 

reader you must present card to a reader or enter PIN code to be deleted, 

otherwise the only one method to remove it from the memory will be full Memory 

Reset

6.3.

 

User identification 

In PRT32 user can be identified by card, PIN or both (card and PIN). The method 

Содержание PRT32

Страница 1: ...PRT32 v1 0 RFID PIN Access Reader Firmware v74 7 Installation and Programming Guide...

Страница 2: ...rs 8 6 2 Managing the users 9 6 3 User identification 9 6 4 Armed and Disarmed Modes 10 6 5 Arming and disarming of a reader 10 6 5 1 Examples 11 6 6 Unlocking a door 11 6 7 Operation with XM 2 I O ex...

Страница 3: ...power up of the reader the LED SYSTEM is on it means that either contents of reader s memory is corrupted or MASTER INSTALLER users are not programmed into a unit In this case reader must be complete...

Страница 4: ...ble to operate with XM 2 I O module nor additional PRT reader 4 General 4 1 Designed function The PRT32 reader has been designed for use in access control installations to enable user identification v...

Страница 5: ...ns for transmission of PIN codes LED BUZZER control input Offline mode Stand alone mode System settings stored in nonvolatile memory Enrolment up to 120 users User identification by a card or PIN code...

Страница 6: ...e code PIN As a result transmission from a reader is not equal to a full code of presented card code or entered PIN In Wiegand format a dual color LED STATUS lights steady in red The LED SYSTEM along...

Страница 7: ...essed Each entry of PIN code must be followed by pressing the key which is treated as the end of a PIN code In RACS format when IN1 is triggered the PRT32 will stop reading cards and PINs till the mom...

Страница 8: ...CLK DTA and IN1 can be configured fro several available functions Note The CLK and DTA lines may operate either as an input or output Installer has to program each line for adequate function The funct...

Страница 9: ...OGGLE LIMITED are solely authorized to control the Armed Disarmed mode of the reader they may have card and or PIN 6 2 Managing the users A new user can be registered in the device following either a...

Страница 10: ...general the reader s Armed Disarmed states have no effect on door unlocking unless the Access disabled when reader armed option will be enabled With this option activated access to the supervised roo...

Страница 11: ...the LED STATUS will change color Note If the option Access disabled when reader armed is enabled and the reader is in Armed mode then in order to unlock a door first you will have to switch the reader...

Страница 12: ...isarmed to Armed mode in order to disable unlocking of a door 6 7 Operation with XM 2 I O extension module In Full stand alone mode the PRT32 requires connection to an external XM 2 I O extension modu...

Страница 13: ...f the reader operates with a Door Contact The alarm indication is carried out over the Alarm Output line and optionally accompanied by the internal buzzer see option Door alarm indication on internal...

Страница 14: ...Offline mode If the unit is dedicated for Offline mode the installer must perform four programming steps Setting the reader to required Offline mode either Full or Simple stand alone mode Programming...

Страница 15: ...RACS data formats the JP1 and JP2 jumpers are used to specify reader s address ID number Note 2 For both Simple and Full stand alone modes the JP1 jumper is used to enter the Memory Reset procedure JP...

Страница 16: ...der 7 4 Memory Reset programming MASTER and INSTALLER users The Memory Reset erases all cards and PINs including MASTER and INSTALLER users Also it causes the reader restores the factory shipped defau...

Страница 17: ...tion mode selected for the reader either Simple Stand alone Mode or Full Stand alone mode the configuration digits C5 and C6 may have different effects for Simple Stand alone mode they configure the r...

Страница 18: ...exist output indicates alarm with a highest priority 7 Door Bell output whenever the door bell event occurs this output goes on for approx 5 seconds C6 0 7 Function settings for the REL2 output on the...

Страница 19: ...d Option Access disabled when reader armed disabled Last step completes the programming and the reader automatically leaves Installer Programming mode and returns to the operating mode either Armed or...

Страница 20: ...first unoccupied memory location with entered PIN his ID number is unknown 4 PIN Add single TOGGLE LTD user with a PIN only The new TOGGLE LTD user is stored in a first unoccupied memory location wit...

Страница 21: ...user with entered ID The user with entered ID is deleted both his card and his PIN are removed a new user can be programmed to use this ID index 0 Delete all users Reader deletes all users cards and P...

Страница 22: ...ong signal Error unknown identifier access denied Two long signals Attempt to assign the same function for two different input lines Three short beeps Command successfully completed OK signal Two shor...

Страница 23: ...ALLER users can be skipped A new factory delivered unit is configured for RACS Online mode with address ID 0 Disconnect power supply before making any electrical connections For installations on a met...

Страница 24: ...IN1 line activated by shorting it with the supply minus When IN1 is triggered it turns the LED OPEN to on and also activate acoustic signal on the internal buzzer TAMP Isolated tamper switch contacts...

Страница 25: ...ule is delivered with plastic box XM 2 Brd The XM 2 PCB module without casing Product History Hardware Firmware Date Description PRT32 v1 0 71 00 18 04 05 The initial product version PRT32 v1 0 72 00...

Страница 26: ...A EN 7 3 2009 _________________________________________________________________________________________ Page 26 of 29 Table List of users Site name Reader location ID Number Card number PIN Type User...

Страница 27: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 27 of 29...

Страница 28: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 28 of 29...

Страница 29: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 29 of 29...

Отзывы: