PRT32 v1.0 fv74.7 Rev. A EN
7/3/2009
_________________________________________________________________________________________
Page 18 of 29
C5
0 – 7
Function settings for the REL1 output on the XM-2 module (when in Full stand-
alone mode) or for the CLK line (when in Simple stand-alone mode):
[0] –
Line off
, line is disabled
[1] –
Door Contact
(input), line shorted to supply minus indicates that
corresponding door is closed
[2] –
Exit Button
(momentary input), shorting the line with supply minus unlocks
a door for time defined by
Door unlock time
[3] –
Arming Disabled
(input), when line is shorted with supply minus reader will
reject any attempt to go into Armed mode
[4] –
Door Lock
(output), output controls the door releasing device (an electric
lock or electric strike).
[5] –
Disarmed Mode
(output), line is triggered for the entire time when reader is
Disarmed
[6] –
Door Alarm
(output), line is used to indicate alarm, output is modulated
according to a detected alarm type, when more then one alarm exist output
indicates alarm with a highest priority.
[7] –
Door Bell
(output), whenever the door bell event occurs this output goes on
for approx. 5 seconds.
C6
0 – 7
Function settings for the REL2 output on the XM-2 module or for the DTA line,
assignments as above.
C7
0 – 3
Function settings for the IN1 line on the reader:
[0] –
Line off
, line is disabled
[1] –
Door Contact
(input), line shorted to supply minus indicates that
corresponding door is closed
[2] –
Exit button
(momentary input), shorting the line with supply minus unlocks
a door for time defined by
Door unlock time
[3] –
Arming Disabled
(input), when line is shorted with supply minus reader will
reject any attempt to go into Armed mode
C8
0 – 3
Function settings for the IN1 line on the XM-2 module – assignments as for C7.
C9
0 – 3
Function settings for the IN2 line on the XM-2 module – assignments as for C7.
C10
0 – 1
The Identification Mode for primary (main) reader:
[0] -
Card or PIN
[1] -
Card and PIN
C11
0 – 1
The Identification Mode for secondary (auxiliary) reader:
[0] -
Card or PIN
[1] -
Card and PIN
C12
0 – 1
Option:
Door alarm indication on internal buzzer
[0] – Disabled
[1] – Enabled
C13
0 – 1
Option:
Access disabled when reader armed
[0] – Disabled
[1] – Enabled